| Plan Review Notes For Permit 14021103 |
| Permit Number |
14021103 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2014-04-14 08:59:39 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) THE STRUCTURE IS LOCATED IN EXPOSURE CATEGORY 'C' | | | AND HAS A 170 MPH VULT WINDSPEED. THE DESIGN PRESSURE | | | FOR THE MULE-HIDE SELF ADHERED ROOF SYSTEM ON PAGE 18 | | | OF NOA NO. 13-0514.12 IS 52.5 PSF. THIS IS NOT ADEQUATE | | | FOR THE PERIMETER AND CORNERS AREAS OF THE FLAT ROOF. | | | SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR ENHANCED FASTENING OF THE BASE SHEET | | | AS REQUIRED BY LIMITATION NUMBER 7 ON PAGE 24 OF THE | | | NOA. FBCR 301.2.1 | | | | | | 2) SPECIFY WHICH METHOD OF ATTACHMENT LISTED IN THE | | | ENTEGRA ROOF TILE PRODUCT APPROVAL (NOA NO.10-1202.01) | | | WILL BE USED TO INSTALL THE ROOF TILE SO THAT IT IS | | | CAPABLE OF RESISTING THE REQUIRED OVERTURN MOMENT. IF | | | AN ADHESIVE WILL BE USED TO ATTACH THE TILE, SUBMIT TWO | | | COPIES OF THE PRODUCT APPROVALS FOR IT. FBCR 301.2.1 & | | | DCA RULE 9N-3 | | | | | | 3) THE VALUE FOR THE WORK IS SPECIFIED AS $2000.00 ON | | | THE APPLICATION. THIS VALUE IS TOO LOW TO RE-ROOF THE | | | SLOPE AND FLAT AREAS OF THIS STRUCTURE. BASED ON | | | MARSHALL AND SWIFT VALUATIONS, THE TOTAL VALUE FOR | | | RE-ROOFING THE 1380 SQFT SLOPED TILE ROOF AND THE 1207 | | | SQFT FLAT ROOF IS $13,200.00. THE VALUE FOR THE WORK | | | HAS BEEN ADJUSTED FROM $2000.00 TO $13,200.00. CITY | | | AMENDMENTS 109.3 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|