2014-02-04 13:32:36BUILDING PLAN REVIEW
 PERMIT: 13121076/ ISOLATED FOOTINGS & FOUNDATION
 ADD: 8151 OKEECHOBEE BLVD
 CONT: P & T CONSTRUCTION
 TEL: (561)324-8055
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 ARCHITECT: TERCILLA COURTEMANCHE 561-478-4457
 RENE TERCILLA
  
 STRUCTURAL: RGD CONSULTING ENGINEERS 561-743-0165
 JAMES FARROR
  
 1ST REVIEW
 DATE: TUESDAY FEB. 04/2014
 ACTION: BUILDING PROVISO
  
 1) 2010 CHAPTER 1 ADMINISTRATIVE CODE 105.13.
 SPECIAL PHASED PERIMETER & ISOLATED FOUNDATION PERMIT
 APPROVAL- NO SLAB WORK
  
 AFTER SUBMITTAL OF THE APPROPRIATE CONSTRUCTION
 DOCUMENTS, THE BUILDING OFFICIAL IS AUTHORIZED TO ISSUE
 A PERMIT FOR THE CONSTRUCTION OF FOUNDATIONS OR ANY
 OTHER PART OF A BUILDING OR STRUCTURE BEFORE THE
 CONSTRUCTION DOCUMENTS FOR THE WHOLE BUILDING OR
 STRUCTURE HAVE BEEN SUBMITTED. THE HOLDER OF SUCH
 PERMIT FOR THE FOUNDATION OR OTHER PARTS OF A BUILDING
 OR STRUCTURE SHALL PROCEED AT THE HOLDER'S OWN RISK
 WITH THE BUILDING OPERATION AND WITHOUT ASSURANCE THAT
 A
 PERMIT FOR THE ENTIRE STRUCTURE WILL BE GRANTED.
 CORRECTIONS MAY BE REQUIRED TO MEET THE REQUIREMENTS OF
 THE TECHNICAL CODES. THIS PROVISION IS ONLY FOR THE
 FLORIDA BUILDING CODE, ALL OTHER AGENCY APPROVALS
 NECESSARY FOR CONSTRUCTION MUST BE SECURED PRIOR TO
 THIS PROVISION BEING APPLIED.
  
  
 2) NOTE THIS PROJECT IS LOCATED IN A A-0 FLOOD ZONE.
 FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES
 SECTION 94-546. PLEASE REVIEW CITY ORDINANCE FOR THE
 CITY REQUIREMENTS REQUIRE AN ADDITIONAL 6 INCHES OF
 ELEVATION. STRUCTURE IS LOCATED IN AN "A0" FLOOD ZONE.
 A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED.
  
 FEMA FORM OMB NO. 1660-0008 EXPIRES:
 JULY 31,2015
  
 DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE
 REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES
 REQUIRED:
 (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE
 PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR
 HEIGHT BEFORE ISSUANCE OF THE BUILDING PERMIT.
 (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND
 ELEVATION CERTIFICATE IS REQUIRED
 (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY
 OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE
 CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR
 ATTENDANT
 A/C PADS OR OTHER SLABS FOR GENERATORS ...
  
 FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR
 USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015.
 FORM. ADDITIONAL INFORMATION ON THE DIFFERENCES, THE
 NEW FORM, AND INSTRUCTIONS ARE AVAILABLE AT:
 HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM
  
 3) THE ELEVATOR PIT MAY BE BELOW THE BASE FLOOD
 ELEVATION AND WILL NEED TO BE DESIGNED TO RESIST THE
 HYDROSTATIC AND HYDRODYNAMIC LOADS AND THE EFFECTS OF
 BUOYANCY AS WELL AS BEING FLOOD PROOFED SO THAT SIX
 INCHES ABOVE THE BASE FLOOD ELEVATION IS WATER TIGHT
 WITH WALLS SUBSTANTIALLY IMPERMEABLE TO THE PASSAGE OF
 WATER. WEST PALM MUNI-CODE SECTION 94-546 PROVISIONS
 FOR FLOOD HAZARD REDUCTION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  