Plan Review Notes
Plan Review Notes For Permit 14011842
Permit Number 14011842
Review Stop B
Sequence Number 3
Notes
Date Text
2014-04-14 09:04:18BUILDING PLAN REVIEW
 PERMIT: 14011842
 ADD: 6007 S DIXIE HWY,
 CONT: COMMUNITY CONSTRUCTION
 TEL: (561)633-2475
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 3RD REVIEW
 DATE: MONDAY APRIL 14/ 2014
  
 ACTION: BUILDING PROVISO:
  
 1) THE DESIGNER OF RECORD HAS PRINTED NEW NOTES ON THE
 PLANS BETWEEN EXISTING FACIAL AND NEW ROOM THAT WAS
 CREATED UNDER THIS PERMIT. THE NEW NOTE INDICATES 32
 INCH CLEAR OPENING BETWEEN 2WALLS, THE WALLS SCALE OUT
 AT 3'-0" BETWEEN WALLS. THE PARALELL WALLS CAN ONLY BE
 REDUCED FOR 24 INCHES AT A CLEAR WIDTH OF 32".
 PLEASE REVIEW:
 2010 FL ACCESSIBILITY CODE 403.5.1 CLEAR WIDTH.
 EXCEPT AS PROVIDED IN 403.5.2 AND 403.5.3, THE CLEAR
 WIDTH OF WALKING SURFACES SHALL BE 36 INCHES (915 MM)
 MINIMUM.
 EXCEPTION:
 THE CLEAR WIDTH SHALL BE PERMITTED TO BE REDUCED TO 32
 INCHES (815 MM) MINIMUM FOR A LENGTH OF 24 INCHES (610
 MM) MAXIMUM PROVIDED THAT REDUCED WIDTH SEGMENTS ARE
 SEPARATED BY SEGMENTS THAT ARE 48 INCHES (1220 MM) LONG
 MINIMUM AND 36 INCHES (915 MM) WIDE MINIMUM.
  
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy