| 2014-04-16 18:28:05 | BUILDING PLAN REVIEW |
| | PERMIT: 14011502 |
| | ADD:7915 S DIXIE HWY SUITE # 7731 |
| | CONT: SISCA CONSTRUCTION |
| | TEL: (561)248-9041 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: WED. APRIL 16/ 2014 |
| | ACTION: DENIED |
| | |
| | NOTE: ONE SET OF PLANS ARE MISSING A3.0, A4.0, A5.0, |
| | A6.0 & A7.0 SHEETS. |
| | |
| | 1-5) COMPLIED. |
| | |
| | 6) 2ND REQUEST PROVIDE MANUFACTURERS CUT SHEETS FOR THE |
| | RUBBER MATS, NO NEW A6.0 SHEET. SHEET A3.0 FLOOR |
| | COVERINGS INDICATE THE USE OF RUBBER MATS RF-1 & RF-2, |
| | PLEASE PROVIDE DOCUMENTATION THESE PRODUCTS ARE IN |
| | OCMPLIANCE WITH THE 2010 FBC-B: |
| | 804.4 INTERIOR FLOOR FINISH REQUIREMENTS. |
| | IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR |
| | COVERING MATERIALS IN EXIT ENCLOSURES, EXIT |
| | PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES NOT |
| | SEPARATED FROM CORRIDORS BY FULL-HEIGHT PARTITIONS |
| | EXTENDING FROM THE FLOOR TO THE UNDERSIDE OF THE |
| | CEILING SHALL WITHSTAND A MINIMUM CRITICAL RADIANT FLUX |
| | AS SPECIFIED IN SECTION 804.4.1. |
| | |
| | 804.4.1 MINIMUM CRITICAL RADIANT FLUX. |
| | INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN |
| | EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS SHALL |
| | NOT BE LESS THAN CLASS I IN GROUPS I-1, I-2 AND I-3 AND |
| | NOT LESS THAN CLASS II IN GROUPS A, B, E, H, M, R-1, |
| | R-2 AND S. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL |
| | COMPLY WITH THE DOCFF-1 ?PILL TEST? (CPSC 16 CFR, PART |
| | 1630). |
| | |
| | EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH |
| | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH |
| | SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE |
| | PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE |
| | REQUIRED, AND MATERIALS COMPLYING WITH THE DOC FF-1 |
| | ?PILL TEST? (CPSC 16 CFR, PART 1630) ARE PERMITTED IN |
| | ANY AREA WHERE CLASS II MATERIALS ARE REQUIRED. |
| | |
| | 7-8) COMPLIED |
| | |
| | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |