| 2014-08-20 14:01:36 | ZONING PLAN REVIEW |
| | ___________________________________________ |
| | |
| | DATE OF REVIEW: 08.20.2014 |
| | PERMIT NO.: 14011422 |
| | ADDRESS: 847 SOUTHERN BOULEVARD |
| | CONTRACTOR/CONTACT: STEVE |
| | TELEPHONE NO.: 561.385.2029 |
| | SCOPE OF REVIEW: CONVERSION OF EXISTING VACANT SPACE |
| | INTO CAFETERIA - EXPANSION OF CONVENIENCE STORE INTO |
| | PREVIOUS SERVICE BAYS. |
| | ___________________________________________ |
| | |
| | REVIEW STATUS: FAILED |
| | ___________________________________________ |
| | |
| | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN |
| | REVIEW COMMENTS: |
| | |
| | 1. IT APPEARS THAT THE AREA IN WHICH THE CAFETERIA IS |
| | PROPOSED TO BE INSTALLED WAS PREVIOUSLY THE SERVICE |
| | BAYS. EXPANSION OF THE EXISTING CONVENIENCE STORE INTO |
| | THIS SPACE WILL REQUIRE THE APPROVAL OF A CLASS B |
| | SPECIAL USE PERMIT. PLEASE CONTACT ME FOR MORE |
| | INFORMATION. |
| | |
| | 2. PLEASE PROVIDE THE OVERALL SQUARE FOOTAGE OF THE |
| | BUILDING. FLOOR AREA ALLOCATED TO THE SALE OF |
| | CONVENIENCE ITEMS SHALL NOT EXCEED 1,500 SQUARE FEET. |
| | |
| | 3. THE REVISED PLANS INDICATE THAT A CONDENSING UNIT IS |
| | NOW BEING ADDED ON THE NORTH SIDE OF THE BUILDING. |
| | PLEASE PROVIDE THE SETBACKS FROM THE PROPERTY LINE TO |
| | THE CONDENSING UNIT. ADDITIONALLY, MECHANICAL EQUIPMENT |
| | SHALL BE SCREENED WITH BRICK, DECORATIVE CONCRETE, |
| | OTHER DECORATIVE MASONRY, OR COMPARABLY DURABLE WOOD |
| | AND STEEL. LANDSCAPING SHALL BE PLANTED AT 2-FOOT |
| | INTERVALS AROUND THE BASE OF THE SCREENING. |
| | |
| | 4. THE REVISED PLANS INDICATE THAT A VENT HOOD / FAN IS |
| | BEING INSTALLED ON THE ROOF. WHAT IS THE HEIGHT OF THE |
| | TOP OF THE VENT HOOD FROM THE TOP OF THE ROOF? IS THERE |
| | AN EXISITNG PARAPET ON THE BUILDING? WOULD LIKE TO SEE |
| | ADDITIONAL DETAIL AS TO HOW THIS HOOD / FAN WILL BE |
| | SCREENED FROM VIEW. |
| | ___________________________________________ |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | ___________________________________________ |
| | |
| | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: |
| | |
| | JOHN ROACH, PRINCIPAL PLANNER |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION |
| | 401 CLEMATIS STREET - P.O. BOX 3147 |
| | WEST PALM BEACH, FLORIDA 33402 |
| | |
| | PHONE: 561.822.1448 |
| | FAX: 561.822.1460 |
| | |
| | EMAIL: [email protected] |
| | |
| | WWW.WPB.ORG |