| Plan Review Notes For Permit 14011234 |
| Permit Number |
14011234 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-01-23 16:16:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SEE FBC 2010 RESIDENTIAL 301, PLEASE SEE DEFINITION | | | OF EXPOSURE B. STRUCTURE APPEARS TO BE LOCATED IN | | | EXPOSURE C, PLEASE REVISE FLAT DECK CALCULATIONS. | | | | | | 2. CALCULATIONS REFER TO PAGE 23, BUT THIS PAGE WAS NOT | | | SUBMITTED. PAGE 31 WAS SUBMITTED, BUT THIS ASSEMBLY | | | REFERS TO GENERAL LIMITATION #9 WHICH DOES NOT ALLOW | | | ENHANCED FASTENING. CALCULATIONS NOT REVIEWED AT THIS | | | TIME UNTIL THE PAGE WITH THE PROPOSED ASSEMBLY IS | | | PROVIDED. | | | | | | | | | |
|