| Date |
Text |
| 2014-06-05 17:07:48 | 6/5/14 NOTE TO FILE: CONNECTED BUILDINGS MEET MINIMUM 5 |
| | FOOT SIDE SETBACK REQUIREMENT. A SETBACK THAT JOGS WITH |
| | THE BUILDING HAS BEEN APPROVED, PER AV, ALLOWING THE |
| | STRUCTURE TO MEET THE MINIMUM TOTAL SIDE SETBACK |
| | REQUIREMENT OF 15 FEET. DK |
| | |
| 2014-06-05 14:47:49 | PLANNING AND ZONING COMMENTS: ***FAILED*** |
| | |
| | REVISED COMMENTS 6/5/14 |
| | [VOID COMMENTS - 5/30/14 (UPDATED 6/2/14)] |
| | |
| | REVISED PLANS CHANGED THE PROPOSED SCOPE OF WORK AND |
| | REQUIRED RE-REVIEW BY ZONING. |
| | |
| | 1. DRAWINGS SHOW A CONNECTION BETWEEN THE ACCESSORY |
| | STRUCTURE AND PRINCIPAL STRUCTURE, HOWEVER, THIS IS NOT |
| | ILLUSTRATED ON THE SITE PLAN. |
| | |
| | 2. ACCESSORY APARTMENTS ARE NOT PERMITTED IN THE SF7 |
| | ZONING DISTRICT. PLEASE BE SURE ADDITION DOES NOT |
| | CONTAIN STOVE, FULL SIZE REFRIDGERATOR (UNDER |
| | COUNTER-STYLE REFRIGERATORS ARE PERMITTED), AND/OR |
| | DOUBLE STYLE SINK. FOR CLARIFICATION OF THE NEW |
| | ADDITION, PLANS SHOULD INDICATE THE SPACE WILL NOT BE |
| | USED AS AN ACCESSORY APARTMENT. |
| | |
| | 3. VERIFY OVERALL HEIGHT OF HOUSE AS DEPICTED ON THE |
| | PLANS. |
| | |
| | 4. PLAN INDICATES AN EXISTING RAILING AROUND THE TOP OF |
| | THE PRINCIPAL STRUCTURE. THE PERMIT TO INSTALL THIS |
| | RAILING AND ROOF IMPROVEMENTS (PERMIT NO. 13010304) HAS |
| | EXPIRED. PLEASE NOTE, PER THE BUILDING DIVISION, ONLY A |
| | 104 FINAL INSPECTION LEFT. - "THEY WILL HAVE TO APPLY |
| | FOR A REISSUE, BUT THEY DON'T NEED A CONTRACTOR, AND |
| | THE FEE WILL BE $80. THE PERMIT WILL BE ISSUED AT THE |
| | FRONT COUNTER IMMEDIATELY AND THE INSPECTION CAN BE |
| | SCHEDULED FOR THE NEXT BUSINESS DAY." |
| | |
| | ADDITIONAL COMMENTS MAY BE GENERATED BASED ON ANY |
| | ALTERATIONS MADE TO THE PLAN. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: |
| | |
| | DANIELLE J. KITTREDGE, AICP |
| | SENIOR PLANNER |
| | PLANNING & ZONING DIVISION |
| | PHONE: (561)-822-1443 |
| | EMAIL: [email protected] |
| 2014-05-30 12:12:21 | PLANNING AND ZONING COMMENTS: ***FAILED*** |
| | |
| | 5/30/14 (UPDATED 6/2/14) |
| | |
| | REVISED PLANS CHANGED THE PROPOSED SCOPE OF WORK AND |
| | REQUIRED RE-REVIEW BY ZONING. |
| | |
| | 1. THE MAXIMUM SQUARE FOOTAGE OF TOTAL FLOOR AREA OF |
| | ALL ROOFED ACCESSORY BUILDINGS ON A PROPERTY SHALL NOT |
| | EXCEED 75 PERCENT OF THE GROSS FLOOR AREA OF THE |
| | PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA OF 1,000 |
| | SQUARE FEET [ZLDR SEC. 94-304(B)(1)]. THE EXPANSION OF |
| | THE EXISTING ACCESSORY STRUCTURE INCREASES THE TOTAL |
| | SQUARE FOOTAGE OF THE ACCESSORY STRUCTURE TO OVER 2,000 |
| | SQUARE FEET AND IS NOT PERMITTED. |
| | |
| | 2. DRAWINGS SHOW A CONNECTION BETWEEN THE ACCESSORY |
| | STRUCTURE AND PRINCIPAL STRUCTURE, HOWEVER, THIS IS NOT |
| | ILLUSTRATED ON THE SITE PLAN. BY CONNECTING THE TWO |
| | BUILDINGS WITH ANYTHING OTHER THAN A CANVAS AWNING ON |
| | THE GROUND LEVEL IS CONSIDERED ATTACHING THE BUIDLINGS |
| | AND THE WHOLE STRUCTURE MUST THEN COMPLY WITH PRINCIPAL |
| | STRUCTURE SETBACKS OF THE SF7 ZONING DISTRICTED. BASED |
| | ON THE SITE DIMENSIONS PROVIDED ONTHE SITE PLAN, THE |
| | STRUCTURES COULD NOT BE ATTACHED AND MEET THE PRINCIPAL |
| | STRUCTURE SETBACKS. |
| | |
| | 3. OTHER ZONING CONSIDERATIONS IF MODFICATIONS ARE |
| | RESUBMITTED: |
| | |
| | A. PLEASE BE SURE ANY CHANGES TO THE PLANS ARE |
| | REFLECTED ACCURATELY ON THE SITE PLAN. |
| | |
| | B. ACCESSORY APARTMENTS ARE NOT PERMITTED IN THE SF7 |
| | ZONING DISTRICT. |
| | |
| | C. VERIFY OVERALL HEIGHT OF HOUSE AS DEPICTED ON THE |
| | PLANS. STRUCTURE APPEARS TO BE HIGHER THAN WHAT WOULD |
| | HAVE ORIGINALLY BEEN PERMITTED. |
| | |
| | D. PLAN INDICATES AN EXISTING RAILING AROUND THE TOP OF |
| | THE PRINCIPAL STRUCTURE. THE PERMIT TO INSTALL THIS |
| | RAILING AND ROOF IMPROVEMENTS (PERMIT NO. 13010304) HAS |
| | EXPIRED. PLEASE NOTE, PER THE BUILDING DIVISION, ONLY A |
| | 104 FINAL INSPECTION LEFT. - "THEY WILL HAVE TO APPLY |
| | FOR A REISSUE, BUT THEY DON'T NEED A CONTRACTOR, AND |
| | THE FEE WILL BE $80. THE PERMIT WILL BE ISSUED AT THE |
| | FRONT COUNTER IMMEDIATELY AND THE INSPECTION CAN BE |
| | SCHEDULED FOR THE NEXT BUSINESS DAY." |
| | |
| | ADDITIONAL COMMENTS MAY BE GENERATED BASED ON ANY |
| | ALTERATIONS MADE TO THE PLAN. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: |
| | |
| | DANIELLE J. KITTREDGE, AICP |
| | SENIOR PLANNER |
| | PLANNING & ZONING DIVISION |
| | PHONE: (561)-822-1443 |
| | EMAIL: [email protected] |
| | |