| Plan Review Notes For Permit 14010859 |
| Permit Number |
14010859 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-01-22 06:02:42 | PLUMBING PROVISO: | | | COMPLIANCE WITH : | | | | | | 2010 FBC-PLUMBING: | | | 608.16.5 CONNECTIONS TO LAWN IRRIGATION SYSTEMS. | | | THE POTABLE WATER SUPPLY TO LAWN IRRIGATION SYSTEMS | | | SHALL BE PROTECTED AGAINST | | | BACKFLOW BY AN ATMOSPHERIC-TYPE VACUUM BREAKER, A | | | PRESSURE-TYPE VACUUM | | | BREAKER OR A REDUCED PRESSURE PRINCIPLE BACKFLOW | | | PREVENTER. A VALVE SHALL NOT BE | | | INSTALLED DOWNSTREAM FROM AN ATMOSPHERIC VACUUM | | | BREAKER. WHERE CHEMICALS ARE | | | INTRODUCED INTO THE SYSTEM, THE POTABLE WATER SUPPLY | | | SHALL BE PROTECTED AGAINST | | | BACKFLOW BY A REDUCED PRESSURE PRINCIPLE BACKFLOW | | | PREVENTER. |
|