| Date |
Text |
| 2014-03-03 13:56:10 | THIS PERMIT IS FOR LIMITED EXPLORATORY DEMOLITION ONLY |
| | AS STATED IN THE DESCRIPTION OF WORK ON THE |
| | APPLICATION. THE SCOPE OF WORK FOR THIS PERMIT IS |
| | LIMITED DEMOLITION TO DETERMINE THE EXISTING STRUCTURAL |
| | CONNECTIONS. A SEPARATE APPLICATION, PERMIT AND REVIEWS |
| | WILL BE REQUIRED TO SHOW THE CONVERSION OF THE GARAGE |
| | TO AN APARTMENT OR ACCESSORY STRUCTURE. |
| | |
| | NOTE: |
| | |
| | ACCORDING TO CITY RECORDS, THIS STRUCTURE WAS |
| | ORIGINALLY CONSTRUCTED AS A DETACHED GARAGE. IT WAS |
| | CONVERTED TO AN APARTMENT WITH A KITCHEN, BEDROOM AND |
| | BATHROOM WITHOUT THE REQUIRED PERMITS OR INSPECTIONS. |
| | UNDER THE 2010 FBC EXISTING BUILDING THIS IS CONSIDERED |
| | A CHANGE OF OCCUPANCY. IN ORDER FOR THIS STRUCTURE-TO |
| | BE BROUGHT INTO COMPLIANCE, IT WILL BE REQUIRED TO |
| | COMPLY WITH THE 2010 FBC EXISTING BUILDING FOR A CHANGE |
| | OF OCCUPANCY FROM A UTILITY TO AN R-3 OCCUPANCY. THIS |
| | CHANGE IS FROM A LOWER HAZARD CATEGORY TO A HIGHER ONE. |
| | THEREFORE, THE FOLLOWING ITEMS WILL NEED TO BE BROUGHT |
| | INTO COMPLIANCE. THE STRUCTURE WILL BE REQUIRED TO |
| | COMPLY WITH THE 2010 FBCR WINDLOAD REQUIREMENTS FOR THE |
| | BUILDING ENVELOPE ( IN ADDITION TO GRAVITY LOADS), |
| | PRODUCT APPROVALS FOR EXTERIOR DOORS AND WINDOWS, |
| | EGRESS REQUIREMENTS, LIGHT AND VENTILATION, SMOKE AND |
| | CARBON MONOXIDE ALARMS, FIRE PROTECTION REQUIREMENTS |
| | (SEPARATION DISTANCE AND ALLOWABLE OPENINGS), THE |
| | REQUIREMENTS OF THE 2010 FBC ENERGY CONSERVATION, THE |
| | REQUIREMENTS OF THE 2010 FBCR MECHANICAL, THE |
| | REQUIREMENTS OF THE 2010 FBCR PLUMBING AND THE |
| | ELECTRICAL SYSTEM WILL BE REQUIRED TO COMPLY WITH THE |
| | 2008 NATIONAL ELECTRICAL CODE. THE PLANS WILL NEED TO |
| | SHOW HOW THE GARAGE WILL BE CONVERTED TO HABITABLE |
| | SPACE IN COMPLIANCE WITH THE 2010 FBC AND 2008 NEC. |