| Date |
Text |
| 2014-02-01 08:34:36 | BUILDING PLAN REVIEW |
| | PERMIT: 14010226 |
| | ADD: 319 CLEMATIS ST SUITE # 112 |
| | CONT: CLAY KOHLMEYER |
| | TEL: (561) 627-3190 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FEB. 01/2014 |
| | ACTION: DENIED |
| | |
| | 1) THE ADDRESS ON THE PERMIT APPLICATION THE ADDRESS & |
| | SHEET LS-1 INDICATES 317 AND OR 319 CLEMATIS ST. OR |
| | BOTH. THE CITY SITE ADDRESS ASWELL AS THE PROPERETY |
| | APPRAISERS SITE HAVE THE SITE ADDRESS AS 319 CLEMATIS |
| | ST. THERE CAN ONLY BE ONE SITE ADDRESS FOR EACH |
| | PROPERTY CONTROL NUMBER. THERE CAN BE SEVERAL TENANT |
| | ADDRESS, ONE FOR EACH UNIT, THE SUITE NUMBERS WILL |
| | FLUXUATE DEPENDING ON THE MOVEMENT OF NEW TENNATCYS. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION 107.2.1 |
| | INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION |
| | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE |
| | MATERIAL. ELECTRONIC MEDIA DOCUMENTS SHALL BE |
| | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION OF THE PROJECT. |
| | |
| | 2) THE LIFE SAFETY PLAN INDICATES AN OCCUPANT LOAD OF |
| | 34 OCCUPANTS BUT DOES NOT SHOW THE TABLES AND CHAIRS |
| | FOR THE OCCUPANTS AND COMPLIANCE WITH 2010 FBC-B 1017.4 |
| | AISLE ACCESSWAYS SEATING AT TABLES, AND COMPLIANCE WITH |
| | 2010 FL ACCESSIBILITY CODE 902.1 GENERAL. DINING |
| | SURFACES AND WORK SURFACES SHALL COMPLY WITH 902.2 AND |
| | 902.3. |
| | ADVISORY 902.1 GENERAL. |
| | DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, |
| | TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK |
| | SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, |
| | STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER |
| | TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON |
| | COUNTERS, AND WHERE COVERED BY THE ADA SCOPING |
| | PROVISIONS. |
| | 902.2 CLEAR FLOOR OR GROUND SPACE. |
| | A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A |
| | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE |
| | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | 902.3 HEIGHT. |
| | THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE |
| | 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 3) NOTE THIS IS A CHANGE IN OCCUPANCY AND WILL NEED TO |
| | BE INDICATED AS SUCH ON THE PERMIT APPLICATION, AND THE |
| | PLANS WILL NEEDTO BE ASSESSED BY PALM BEACH COUNTY |
| | IMPACT FEE OFFICE BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |