| 2014-01-10 16:44:41 | BUILDING PLAN REVIEW |
| | PERMIT: 13121049 |
| | ADD: 10130 NORTHLAKES BLVD # 218 |
| | CONT: VENTURA ARCHITECTURE DEVELOPMENT |
| | TEL: (954) 423-1362 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1STREVIEW |
| | DATE: FRIDAY JAN.10/ 2014 |
| | ACTION: PROVISO APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) THE PRODUCT APPROVAL SUBMITTED FOR THE GLAZED |
| | STOREFRONT NOA 11-1207.07 TRULITE REGISTER FG-4500/ 450 |
| | EZ IS A NON-IMPACT GLAZED SYSTEM. PLEASE PROVIDE |
| | COMPLIANCE WITH 2010 FBC-B 1609.1.2 PROTECTION OF |
| | OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING STORM |
| | SHUTTERS. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE |
| | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(E) SHUTTER. |
| | |
| | PROVIDE STORM PANEL INFORMATION WITH INSTALLATION |
| | SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND |
| | MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC |
| | 1609.1.4. |
| | |
| | FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 & |
| | EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE |
| | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| | SPANS/WIDTHS, UNIT BAR REINFORCING REQUIREMENTS, WALL |
| | PRESSURE ZONES, SLAT TYPES, ETC. |
| | |
| | 2) SHEET A2 SECTIONS 1,2 & 3 2010 FBC-ENERGY 502.2.1.2 |
| | CEILING INSULATION. INSULATION INSTALLED ON A SUSPENDED |
| | CEILING WITH REMOVABLE CEILING TILES SHALL NOT BE |
| | CONSIDERED PART OF THE MINIMUM THERMAL RESISTANCE OF |
| | THE ROOF INSULATION UNLESS THE ROOF/CEILING CAVITY IS |
| | SEALED FROM THE EXTERIOR ENVIRONMENT. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |