| Plan Review Notes For Permit 13120916 |
| Permit Number |
13120916 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-01-23 11:12:51 | | | | BUILDING PLAN REVIEW | | | PERMIT: 13120916 | | | ADD: 1815 PALM BEACH LAKES SHELL BLDG "E" | | | CONT: EMJ | | | TEL: (561 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 1ST REVIEW | | | DATE: THURSDAY JAN. 23/ 2014 | | | ACTION: BUILDING PROVISO | | | | | | 1) SHEET A141 ROOF PLAN INDICATES ZONE # 1 TO BE | | | MECHANICALLY FASTENED, NOTE ON PLAN ZONES 2 & 3 THE | | | ROOFING IS TO BE FULLY ADHERED SINGLE PLY TPO. | | | | | | NOA 12-0514.04 FIRESTONE 1-30 PAGES TPO OVER STEEL DECK | | | PAGE 12 HIGHLIGHTED SINGLE PLY TPO, STEEL INSULATED | | | DECK 22 GAUGE/ 6'-0" SPACING | | | ISO 95+GL MIN 2" THICK MAXIMUM DESIGN FOR MECH FASTENED | | | -75 PSI | | | | | | NO SHEETS HIGHLIGHTED IN THE NOA FOR FULLY ADHERED FOR | | | ZONES 2 & 3, ADDITIONAL INFORMATION IS REQUIRED. 2010 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 107.2.1.3. | | | | | | ======================================================= | | | ====================== | | | | | | NOA- 13-0603.19 GAF ENERGY GAURD |
|