| 2013-12-30 09:02:39 | BUILDING PLAN REVIEW |
| | PERMIT: 13120664 |
| | ADD: 221 CLEMATIS ST. 3RD FL. TENANT BUILD-OUT |
| | CONT: GALFA CEE CO. |
| | TEL: (561)718-9509 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: DEC. 30/2013 |
| | ACTION: PROVISO |
| | |
| | MECHANICAL APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) SHEET M-1 THE CONFERENCE ROOM # 106 SHOWS A 14 INCH |
| | DIAMETER DUCT SUPPLYING 720 CFM FULL HEIGHT PARTITION |
| | (P4) AND NO TRANSFER GRILLE. PLEASE PROVIDE COMPLIANCE |
| | WITH |
| | 2010 FBC-MECHANICAL 601.4 BALANCED RETURN AIR. |
| | |
| | 2) SHEET M-2 INDICATES A NEW ROOF TOP A/C STAND, PLEASE |
| | PROVIDE THE PRODUCT APPROVAL IN COMPLIANCE WITH RULE |
| | 9N-3 (31)(G). |
| | |
| | 3) SEE ATTACHMENT FROM MASTER PERMIT # 07110013 & |
| | MECHANICAL REVISION # 09050030 FOR EXISTING DUCT WORK, |
| | SHAFT LOCATION, FIRE DAMPER LOCATION AND ACCESS DOORS, |
| | FOR REFERENCE ONLY, VERIFY AT SITE. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |