| Notes |
| Date |
Text |
| 2013-12-05 17:16:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ROOF FORM IS ILLEGIBLE. PLEASE SUBMIT LEGIBLE | | | COPIES. | | | | | | 2. SPECIFY TYPE OF WOOD DECK - PLYWOOD OR PLANK. | | | | | | 3. PROPOSED DESIGN PRESSURES ARE NOT CLEAR BUT APPEAR | | | TO BE 76.019 IN THE CORNER, PROVIDE CALCULATIONS. | | | EXPOSURE WAS LEFT BLANK; THIS IS EXPOSURE D. IT IS NOT | | | CLEAR HOW PRESSURES LOWER THAN EXPOSURE C HAVE BEEN | | | DETERMINED. ZONE 3, EXPOSURE D, HAS A DP OF -127.3 | | | USING TABLES FBC RESIDENTIAL 2010 301.2(2), (3). | | | | | | 4. DRAIN INSTALLATION REQUIRES A PLUMBING PERMIT. | | | PROVIDE PLAN AND PERMIT APPLICATION. | | | | | | | | | | | | | | | |
|