2013-12-19 13:33:48BUILDING PLAN REVIEW
 REVISION : 13120085
 PERMIT: 13070818
 ADD: 1807 PALM BEACH LAKES
 CONT: HALEY CONSTRUCTION
 TEL: (954)202-7000 JESSICA
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURSDAY, DEC. 19/2013
 ACTION: BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) ADDITIONAL INFORMATION IS REQUIRED TO DETERMINE CODE
 COMPLIANCE ON THE OVERHEAD GARAGE DOORS LOCATED ON
 SHEET A1.3 & A4.02 DETAIL # 5. I'VE SPOKEN WITH PROJECT
 ARCHITECT JAMIE KNOLLMILLER AND TTHE OVERHEAD DOORS
 WILL BE IN THE HORIZONTAL POSITION. SINCE THERE IS
 GLAZING IN THESE OVERHEAD DOORS PLEASE SUBMIT PRODUCT
 INFORMATION PROVIDING CODE COMPLIANCE WITH SECTION:
 2405.1 SCOPE.
 THIS SECTION APPLIES TO THE INSTALLATION OF GLASS AND
 OTHER TRANSPARENT, TRANSLUCENT OR OPAQUE GLAZING
 MATERIAL INSTALLED AT A SLOPE MORE THAN 15 DEGREES
 (0.26 RAD) FROM THE VERTICAL PLANE, INCLUDING GLAZING
 MATERIALS IN SKYLIGHTS, ROOFS AND SLOPED WALLS.
  
 2405.2 ALLOWABLE GLAZING MATERIALS AND LIMITATIONS.
 SLOPED GLAZING SHALL BE ANY OF THE FOLLOWING MATERIALS,
 SUBJECT TO THE LISTED LIMITATIONS.
  
 1. FOR MONOLITHIC GLAZING SYSTEMS, THE GLAZING MATERIAL
 OF THE SINGLE LIGHT OR LAYER SHALL BE LAMINATED GLASS
 WITH A MINIMUM 30-MIL (0.76 MM) POLYVINYL BUTYRAL (OR
 EQUIVALENT) INTERLAYER, WIRED GLASS, LIGHT-TRANSMITTING
 PLASTIC MATERIALS MEETING THE REQUIREMENTS OF SECTION
 2607, HEAT-STRENGTHENED GLASS OR FULLY TEMPERED GLASS.
  
 2. FOR MULTIPLE-LAYER GLAZING SYSTEMS, EACH LIGHT OR
 LAYER SHALL CONSIST OF ANY OF THE GLAZING MATERIALS
 SPECIFIED IN ITEM 1 ABOVE.
  
 ANNEALED GLASS IS PERMITTED TO BE USED AS SPECIFIED
 WITHIN EXCEPTIONS 2 AND 3 OF SECTION 2405.3.
  
 FOR ADDITIONAL REQUIREMENTS FOR PLASTIC SKYLIGHTS, SEE
 SECTION 2610. GLASS-BLOCK CONSTRUCTION SHALL CONFORM TO
 THE REQUIREMENTS OF SECTION 2101.2.5.
  
 JAMES A. WITMER CBO