Plan Review Notes
Plan Review Notes For Permit 13110669
Permit Number 13110669
Review Stop B
Sequence Number 1
Notes
Date Text
2013-11-30 10:28:25BUILDING PLAN REVIEW
 PERMIT: 13110669
 ADD: 1751 PALM BEACH LAKES # E115
 CONT: TO BE DETERMINED
 CONTACT: KARI NEVILLE
 TEL: (561) 373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: SAT. NOV. 30/2013
  
 ACTION: DENIED
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
 1) SHEETS A-110 & E-111 BOTH SHOW AN EXIT LIGHT IN THE
 SHOWROOM DIRECTLY IN FRONT OF THE STOCKROOM (PRE-SALES
 ROOM), A REVISION IS REQUIRED EITHER REMOVE THE EXIT
 SIGN OR PROVIDE COMPLIANCE WITH:
 2010 FBC-B 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING
 SPACES 4. EGRESS SHALL NOT PASS THROUGH KITCHENS,
 STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
 PURPOSES. EXCEPTIONS:
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 2) BUILDING PROVISO:
 PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED. PLEASE PROVIDE THE PERMIT NUMBER, ADDRESS
 WITH SUITE NUMBER WITHIN THE DOCUMENT.
 TRACY BECKER, TENANT COORDINATOR
 [email protected]
 618-514-2128
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CITY OF WEST PALM BEACH, FL
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  