2013-12-19 16:12:00NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC
  
 1- PLANS NEED TO SPECIFY A BATHROOM LOCATED WITH
 MAXIMUM POSSIBLE PRIVACY WITH A DOOR THAT HAS A 29"
 CLEAR OPENING AS REQUIRED BY SEC. R320 OF 2010
 FBC-RESIDENTIAL.
  
 2- PROVIDE MANUFACTURER'S SPECS FOR OUTDOOR KITCHEN BBQ
 DESIGNED TO BE INSTALLED IN PORCH AS SHOWN ON PLANS.
 SEC. M1901.2 AND G2408.1 OF 2010 FBC-RESIDENTIAL.
  
 3- TYPICAL WALL SECTION ON SHEET A801:
 A) SPECIFY 12" MIN. FOOTING DEPTH AS REQUIRED BY SEC.
 R403.1.4. REVISE AS REQUIRED.
  
 B) SPECIFY THE MINIMUM FOOTING HEIGHT ABOVE FINISHED
 GRADE AS REQUIRED BY SEC. R404.1.6.
  
 C) CONCRETE ROOF TILE: SPECIFY NAIL TYPE, SIZE AND
 NUMBER AS REQUIRED BY SEC. 107.2.1.2 OF CITY AMENDMENTS
 TO FBC.
  
 4- VALUATION UPDATED AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. THE PERMIT FEE BALANCE IS $11,992.60.
  
 5- SHEET A901: REVISE ALL WINDOW AND DOOR STRUCTURAL
 BUCK DETAILS. BUCK NEEDS TO PROVIDE FULL SUPPORT TO THE
 WINDOW/DOOR FRAME AS REQUIRED BY SEC. R612.10.2.1.
  
 6- PROVIDE DRAINAGE PLAN. SEC. R401.3
  
 7- SHEET S-2: REVISE THE WIND PRESSURES ON OPENINGS.
 SEC. R301. *(A) SPECIFY WHERE ARE THE A, B AND C ZONES.
 **(B) INFORMATION ON THIS PAGE DOESN'T MATCH
 INFORMATION SHOWN ON STRUCTURAL NOTES ON SHEET S-4.
 ***C) WHY THE DESIGN PRESSURES FOR ZONE B AND C ARE THE
 SAME?. ****(D) SPECIFY THE ULTIMATE WIND SPEED AND THE
 NOMINAL WIND SPEED. COORDINATE WITH ITEM #9 BELOW.
  
 8- SHEET S-3: REVISE FOOTING DEPTH TO COMPLY WITH ITEM
 #3(A) AND #3(B) ABOVE. SEC. 107.2.1 CITY AMENDMENTS.
  
 9- SHEET S-4:
 *(A) DESIGN PRESSURES FOR THE ROOF COMPONENT AND
 CLADDING DESIGN PRESSURES ARE TOO LOW. PROVIDE
 CALCULATIONS. COORDINATE WITH ITEM #7 ABOVE. SEC.
 107.2.1.3 CITY AMENDMENTS.
  
 **(B) REVISE ALL DOORS AND WINDOWS STRUCTURAL BUCK
 DETAILS. NEED TO SPECIFY BUCK FASTENING. AND, BUCK NEED
 TO PROVIDE FULL SUPPORT TO THE DOOR/WINDOW FRAME AS
 REQUIRED BY SEC. R612.10.2.1. ***NOTE: COORDINATE WITH
 ITEM #5 ABOVE. SEC. R612.10.2.1.
  
 ***(C) SPECIFY FASTENING FOR GARAGE DOOR STRUCTURAL
 BUCK. SEC. R301.1.
  
 10- SHEET S-5. REVISE THE DESIGN PRESSURES SHOWN ON THE
 ROOF WIND ZONE DIAGRAM. COORDINATE WITH ITEM #9(A)
 ABOVE. SEC. R301.
  
 11- ENERGY CALCULATIONS ARE TAKEN THE CEILING FAN
 CREDITS. SHOW ON PLANS CEILING FANS ON ALL ROOMS
 (INCLUDING THE LIVING AREA AND LIBRARY) AND SIZES AS
 REQUIRED BY SEC. 405.6.6 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 12- REVISE ENERGY CALCULATIONS SUBMITTED. SEC.
 103.2.1.1.1 OF 2010 FBC-ENERGY CONSERVATION.
 A) HOT WATER SYSTEM IS NOT ELECTRIC. SEE PLANS.
 B) THERE ARE NOT WOOD DOORS. SEE PLANS AND PRODUCT
 APPROVALS SUBMITTED.
 C) PROVIDE CORRECT NAME OF BUILDER.
 D) PERMIT OFFICE IS WEST PALM BEACH, NOT PALM BEACH
 COUNTY.
 E) JURISDICTION NUMBER IS 604700, NOT 601000.
  
 13- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A)ALUMINUM FIXED WINDOWS. NOA 11-1110.15 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. VISIT THE MIAMI-DADE WEBSITE
 AND DOWNLOAD CURRENT NOA.
 B) LARGE FIXED WINDOWS SHOWN ON THE LIVING AREA. (4'-0"
 X 11'-0"). SEE PLANS.
 C) ALUMINUM CASEMENT WINDOWS NOA 11-1110.18 SUBMITTED
 EXPIRED ON MAY 22, 2013. NEED CURRENT NOA.
 D) ALUMINUM MULLIONS. NOA 11-0922.01 WAS SUPERSEDED BY
 MIAMI-DADE. NEED CURRENT NOA. AND, CLEARLY SPECIFY
 MULLION SIZES TO BE USED (SPECIALLY THOSE SHOWN ON
 LIVING AREA LARGE WINDOWS) TO VERIFY COMPLIANCE WITH
 THE DESIGN PRESSURES.
 E) ENTRY DOOR SIZE AS SHOWN ON PLANS.
 F) ALL SIMPSON AND USP STRUCTURAL CONNECTORS SPECIFIED
 ON PLANS AND DETAILS. ALL FLORIDA PRODUCT APPROVAL
 NUMBER SHOWN ON PLANS NEED TO BE UPDATED TO THE CURRENT
 2010 FBC.
 G) PRECAST LINTELS AS SHOWN ON PLANS.
 H) 16'-0" WIDE GARAGE DOORS. ONLY DRAWINGS FOR 9'-0"
 GARAGE DOORS WERE SUBMITTED.
  
 14- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL
 PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 15-CLARIFY WHY SUBMITTING PRODUCT APPROVALS FOR SINGLE
 HUNG WINDOWS. PLANS DON'T SHOW ANY SINGLE HUNG WINDOWS.
 (SINGLE HUNG WINDOWS MAY NOT COMPLY WITH BEDROOM EGRESS
 WINDOWS. THAT'S WHY IS IMPORTANT TO CLARIFY). SEC.
 107.2.1 CITY AMENDMENTS.
  
 16- NEED TO SPECIFY CARBON MONOXIDE ALARMS AS REQUIRED
 BY SEC. R315
  