| Plan Review Notes For Permit 13101152 |
| Permit Number |
13101152 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-11-22 16:35:09 | 11/22/13 TALKED TO MS. TERRY. THEY WILL ADDRESS PROVISO | | | ITEMS BEFORE PERMIT ISSUANCE. JG. | | 2013-11-18 17:51:14 | | | | | | | | | | | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- SHEET S-2: REVISE ROOF LOADS. NEED 20PSF ATTIC LIVE | | | LOAD. REQUIRED BY TABLE R301.5. SEE FOOTNOTES "B" AND | | | "G". | | | | | | 2- PROVIDE PRODUCT APPROVALS FOR : *A) 18' WIDE GARAGE | | | DOOR. **B) WINDOW MULLION. NOA 11-0922.01 SUBMITTED WAS | | | SUPERSEDED BY MIAMI-DADE. ***C) FIXED WINDOWS. NOA | | | 11-1110.15 SUBMITTED WAS SUPERSEDED BY MIAMI-DADE. | | | | | | 3- DESIGNER OF RECORD TO APPROVED PRODUCT APPROVALS. | | | SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 4- SUMMER KITCHEN: PROVIDE COMPLETE MANUFACTURER'S | | | SPECS FOR "BULL ANGUS GRILL" THAT IS DESIGNED TO BE | | | INSTALLED IN A COVERED PATIO AS SHOWN ON PLANS. SEC. | | | M1302.1 OF 2010 FBC-RESIDENTIAL. | | | | | | |
|