2014-03-18 12:52:27****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
 [email protected]
  
 FROM PREVIOUS LIST #2:
  
 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 THE ROOF, FAC9N-3. PRODUCT APPROVAL TO BE REVIEWED
 PRIOR TO SUBMITTAL, FBC 107.
  
 3RD REVIEW: MY APOLOGIES THAT THIS COMMENT WAS NOT
 CLEAR. REVIEW IS TO BE DONE BY DESIGNER OF RECORD
 (ARCHITECT) PRIOR TO SUBMITTAL TO THE BUILDING
 DEPARTMENT.
  
 2. "METAL ROOF" IS SPECIFIED ON THE PLAN. SEE FBC
 1507.4.2; 1/4" PER 12" IS ACCEPTABLE FOR STANDING SEAM.
 1/2" PER 12" REQUIRED FOR LAPPED, NON SOLDERED SEAM
 METAL ROOFS WITH APPLIED LAP SEALANT. IF A STANDING
 SEAM IS NOT PROPOSED, REVISE PITCH.
  
 3RD REVIEW: TWO SETS REQUIRED FBC 107. MINIMUM SLOPE IS
 2:12 FOR THIS PRODUCT. PLEASE CORRELATE WITH PLAN WHICH
 SPECIFIES 1/4" PER 12".
  
  