| Plan Review Notes For Permit 13100921 |
| Permit Number |
13100921 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-10-30 07:33:31 | REVISED SHEETS A-1, A-2, A-5 AND A-6 ARE APPROVED AS | | | RED-LINED. | | | | | | THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR STEEL | | | STRUCTURAL ROOF PANEL (NOA NO. 08-0827.20) IS DENIED. | | | THE DESIGNER OF RECORD IS REQUIRED TO REVIEW AND | | | APPROVE THE PRODUCT APPROVAL IN WRITING. THIS PRODUCT | | | IS DESIGNED AND TESTED TO BE INSTALLED OVER A METAL | | | FRAME ROOF AS A STRUCTURAL COMPONENT OF THE MAIN WIND | | | FORCE RESISTING SYSTEM, RATHER THAN CLADDING. THE PLANS | | | INDICATE THAT THIS STRUCTURE HAS WOOD TRUSSES COVERED | | | WITH A PLYWOOD DECK. SINCE IT WILL NOT BE INSTALLED PER | | | THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, IF YOU | | | WISH TO USE THIS PRODUCT YOU WILL NEED TO SUBMIT IT AS | | | ALLOWED BY CITY AMENDMENT 104.11 ALTERNATIVE | | | MATERIALS,DESIGN AND METHODS OF CONSTRUCTION FOR THE | | | BUILDING OFFICIALS APPROVAL. THE FASTENER SIZE,TYPE, | | | SPACING, SPANS AND ROW SPACING WILL NEED TO BE | | | SPECIFIED AND SHOWN TO BE COMPLIANT WITH THE APPLICABLE | | | CODE. (2007 FBC W/2009 REVISIONS) |
|