| Date |
Text |
| 2013-11-04 09:16:51 | BUILDING PLAN REVIEW |
| | PERMIT: 13100847 |
| | ADD: 871 VILLAGE BLVD # 601 |
| | CONT: PAGE CONTRACTING |
| | TEL: (954)868-7561 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MONDAY NOV. 04/ 2013 |
| | ACTION: BUILDING PROVISOS: |
| | |
| | 1) SHEET A2.00 THE DESIGNER INDICATES TTHE USE OF 1 |
| | HOUR FIRE RATED TENANT SEPERATION WALLS, PLEASE PROVIDE |
| | COMPLIANCE WITH THE FOLLOWING : |
| | 2010 FBC-B 713.6 FIRE WALLS, FIRE BARRIERS, FIRE |
| | PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY |
| | OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE |
| | EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR |
| | STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY |
| | HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE |
| | ANY DECORATIVE CEILING AND IN CONCEALED SPACES. |
| | SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: ?FIRE |
| | AND SMOKE BARRIER ? PROTECT ALL OPENINGS.? |
| | |
| | 2) SHEET A8.02 THE PLANS SHOW A ELEVATION VIEW OF THE |
| | CASH WRAP BUT NO DIMENSIONS, PLEASE COMPLY WITH: 2010 |
| | FL ACESSIBILITY CODE 904.4 SALES AND SERVICE COUNTERS. |
| | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| | SERVICE COUNTER TOP. |
| | 904.4.1 PARALLEL APPROACH. |
| | A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915 |
| | MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM |
| | ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR |
| | OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED |
| | FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915 |
| | MM) MINIMUM LENGTH OF COUNTER. |
| | |
| | EXCEPTION: WHERE THE PROVIDED COUNTER SURFACE IS LESS |
| | THAN 36 INCHES (915 MM) LONG, THE ENTIRE COUNTER |
| | SURFACE SHALL BE 36 INCHES (915 MM) HIGH MAXIMUM ABOVE |
| | THE FINISH FLOOR. |
| | |
| | 904.4.2 FORWARD APPROACH. |
| | A PORTION OF THE COUNTER SURFACE THAT IS 30 INCHES (760 |
| | MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM |
| | SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH |
| | 306 SHALL BE PROVIDED UNDER THE COUNTER. A CLEAR FLOOR |
| | OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED |
| | FOR A FORWARD APPROACH TO THE COUNTER. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |