| 2013-11-01 08:23:33 | BUILDING PLAN REVIEW |
| | PERMIT: 13100840 |
| | ADD: 1751 PALM BEACH LAKES # E113 |
| | CONT: TO BE DETERMINED |
| | TEL: (561 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: FRIDAY, NOV 1/ 2013 |
| | ACTION: PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) PB OUTLET MALLS: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| | NOTARIZED. |
| | |
| | 2) SHEET T2 PARTITION OR SIMILAR CONSTRUCTION FROM |
| | EGRSEE AISLE AND STOCKROOM FBC-B 1014.2(4) EXCEPTION |
| | 2(2.4) THE SHELVING SEPERATING THE STOCKROOM FROM |
| | EGRESS AISLE, THE BACK OF SHELVING ADJACENT TO EGRESS |
| | AISLE TO HAVE SOLID BACKING. |
| | |
| | 3) SHEET A4 CASH WRAP DOES NOT HAVE ELEVATIONS FOR CASH |
| | WRAP, TO COMPLY WITH 2010 FL ACCESSIBILITY CODE .904.4 |
| | SALES AND SERVICE COUNTERS. |
| | SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| | 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| | COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| | SERVICE COUNTER TOP. |
| | 904.4.1 PARALLEL APPROACH. |
| | A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915 |
| | MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM |
| | ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR |
| | OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED |
| | FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915 |
| | MM) MINIMUM LENGTH OF COUNTER. |
| | EXCEPTION: WHERE THE PROVIDED COUNTER SURFACE IS LESS |
| | THAN 36 INCHES (915 MM) LONG, THE ENTIRE COUNTER |
| | SURFACE SHALL BE 36 INCHES (915 MM) HIGH MAXIMUM ABOVE |
| | THE FINISH FLOOR. |
| | 904.4.2 FORWARD APPROACH. |
| | A PORTION OF THE COUNTER SURFACE THAT IS 30 INCHES (760 |
| | MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM |
| | SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH |
| | 306 SHALL BE PROVIDED UNDER THE COUNTER. A CLEAR FLOOR |
| | OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED |
| | FOR A FORWARD APPROACH TO THE COUNTER. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |