| 2014-02-21 14:25:20 | RECORDS APPEAR TO INDICATE THE SECOND FLOOR SPACE IS AN | | | EXISTING DWELLING UNIT. IS IT THE INTENT OF THIS | | | APPLICATION FOR IMPROVEMENT TO CONVERT THE EXISTING | | | BUILDING INTO A TWO DWELLING BUILDING, OR IS THIS AN | | | EXTENSION OF LIVING AREA WITH A SINGLE STRUCTURE | | | CONSTITUTING ON DEWLLING? IF TWO UNITS, YOU MUST COMPLY | | | WITH THE REQUIREMENTS FOR FIRE SEPARATION PER FBC R | | | 302.3 1-HR . THE SUMBITTED PLAN AND PROPERTY APPRAISER | | | RECORDS APPEAR TO INDICATE THE EXISTING SPACE PROPROSED | | | FOR IMPROVEMENT IS A STORAGE AREA. IN THAT CASE, THE | | | DESIGN PARAMETERS MUST CONSIDER FBC-E CHAPTER 9 CHANGE | | | OF OCCUPANCY. FBC 107.3.5.3 ? PROVIDE AN ENERGY | | | SUBMITTAL. PROVIDE DETAILS FOR THE WINDOW OPENING | | | PROPOSED TO BE FILLED IN. THIS REVIEW IS INCOMPLETE | | | PENDING FURTHER CLARIFICATION OF THE INTENT OF THE | | | APPLICATION. | | 2014-02-18 13:58:44 | MCDOUGAL |
|