2013-12-18 16:07:51RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS. SEC. 101.4.3 OF 2010
 FBC-ENERGY CONSERVATION.
 (REPEAT COMMENT. NOT ADDRESSED).
 ***NOTE: PLEASE MAKE SURE FORM IS FILLED COMPLETELY,
 INCLUDING THE INFORMATION ON TOP OF FORM AND IS
 CERTIFIED AND DATED BY ALL THE PARTIES AT BOTTOM OF
 FORM.
  
 2- PROVIDE COMPLETE DRAWINGS SHOWING FRAMING DETAILS
 AND SPECIFICATIONS SHOWING COMPLIANCE WITH SEC. R301 OF
 2010 FBC-RESIDENTIAL.
  
 *(A) DRAWINGS SUBMITTED DON'T SPECIFY STRUCTURAL BUCK
 ATTACHMENT. REVISE AS REQUIRED.
 **(B) NEW DOOR JAMB, SILL AND HEADER DETAILS SUBMITTED
 ARE FOR WINDOWS NOT FOR SLIDING GLASS DOORS. REVISE AS
 REQUIRED.
 ***(C) STRUCTURAL BUCK NEED TO PROVIDE FULL SUPPORT TO
 THE SLIDING GLASS DOOR FRAME AS REQUIRED BY SEC.
 R612.10.2.1 OF 2010 FBC-RESIDENTIAL. REVISE DETAILS AS
 REQUIRED.
  
 3- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 REVISE VALUE TO INCLUDE ALL THE LABOR, MATERIALS,
 OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES. SEC.
 109.3 CITY AMENDMENTS TO FBC.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 4- MASTER BEDROOM: THERE WAS AN SLIDING GLASS DOOR
 LEADING OUT TO THE PORCH. THE EGRESS FROM THE MASTER
 BEDROOM IS AFFECTED. SPECIFY THE TYPE AND SIZE OF
 EXISTING WINDOW TO VERIFY IF THIS WINDOW WILL COMPLY
 WITH THE EGRESS REQUIREMENTS. SEC. 601.2 OF 2010
 FBC-EXISTING BUILDING.
  
 *(A) DRAWINGS SUBMITTED DON'T SHOW SIZE OF HORIZONTAL
 SLIDER WINDOW.
 **(B) DRAWINGS SUBMITTED SHOW WINDOWS ON THE NORTH WEST
 WALL. (NORTH ARROW ON KEY MAP SUBMITTED NEED TO BE
 REVISED TO MATCH ACTUAL BUILDING ORIENTATION. SEE
 AERIAL MAP ON PROPERTY APPRAISAL RECORDS). THIS WALL IS
 ON THE ZERO LOT LINE AND OPENINGS ARE NOT ALLOWED.
 REVISE DRAWINGS AS REQUIRED.
 ***NOTE: ANY OPENINGS ON THE THIS WALL NEED TO BE
 ENCLOSED WITH ONE HOUR FIRE RATED ASSEMBLY. (NOTE:
 OPENINGS ON THIS WALL WILL BE VERIFIED BY THE
 INSPECTOR).
  
 ****NOTE: PLEASE PROVIDE A RESPONSE LETTER ADDRESSING
 EACH COMMENT. THIS WILL EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712