| Date |
Text |
| 2013-11-02 12:54:31 | 1717 EDGAR STREET |
| | PERMIT #13100403 |
| | REVIEW COMMENTS - FIRE DEPARTMENT |
| | |
| | HEADROOM: THE BAR JOISTS ABOVE THE MEZZANINE ARE |
| | LOCATED WITHIN 7'-6" OF THE FLOOR DECK. |
| | |
| | STAIR HANDRAILS& GUARDRAILS: GUARDS, AT LEAST 42-INCHES |
| | TALL, SHALL BE PROVIDED AT THE OPEN SIDES OF MEANS OF |
| | EGRESS (STAIRS, MEZZANINE, ETC.) THAT EXCEED 30-INCHES |
| | ABOVE THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE |
| | OF A 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF |
| | 34-INCHES. THE TRIANGULAR OPENINGS FORMED BY THE RISER, |
| | TREAD AND BOTTOM ELEMENT OF THE GUARDRAIL SHALL |
| | PROHIBIT THE PASSAGE OF A 6-INCH DIAMETER SPHERE. |
| | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. |
| | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND |
| | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, |
| | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE |
| | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE |
| | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT |
| | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A |
| | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN |
| | 2 INCHES. |
| | |
| | STAIR RISERS: INDICATE THE HEIGHT OF THE STAIR RISERS. |
| | |
| | INDICATE THE LOCATIONS OF MEZZANINE LIGHTING. IS |
| | LIGHTING TO BE PROVIDED TO ILLUMINATE THE AREA BELOW |
| | THE MEZZANINE? |
| | |
| | STRUCTURES WITH LIGHT FRAME FLOOR CONSTRUCTION SHALL BE |
| | IDENTIFIED WITH A SIGN AFFIXED TO THE BUILDING. THE |
| | SIGN SHALL FEATURE A MALTESE CROSS 8-INCHES WIDE AND |
| | 8-INCHES TALL AND BE OF A BRIGHT RED REFLECTIVE COLOR |
| | AND BEAR THE LETTER F DESIGNATION PER FLORIDA STATUTE |
| | 633.027 AND FLORIDA ADMINISTRATIVE CODE 69A-60.0081. |
| | |
| | WESLEY JOLIN |
| | FIRE INVESTIGATOR & INSPECTOR |
| | OFFICE OF THE FIRE MARSHAL |
| | WEST PALM BEACH FIRE RESCUE |
| | [email protected] |
| | (561) 805-6730 |
| | |