| | BUILDING PLAN REVIEW |
| | PERMIT: 13100309 |
| | ADD: 1721 PALM BEACH LAKES # E-411 |
| | CONT: TO BE DETERMINED |
| | TEL: |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: THURS OCT. 17/ 2013 |
| | ACTION: BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) PB OUTLET MALLS: |
| | BUILDING PROVISO: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| | NOTARIZED. |
| | |
| | 2) SHEET A2.4 DETAIL # 6 ACCESSIBLE FITTING ROOM, BENCH |
| | TO COMPLY WITH: |
| | 903.4 BACK SUPPORT. |
| | THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE |
| | AFFIXED TO A WALL. BACK SUPPORT SHALL BE 42 INCHES |
| | (1065 MM) LONG MINIMUM AND SHALL EXTEND FROM A POINT 2 |
| | INCHES (51 MM) MAXIMUM ABOVE THE SEAT SURFACE TO A |
| | POINT 18 INCHES (455 MM) MINIMUM ABOVE THE SEAT |
| | SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES (64 MM) |
| | MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED |
| | HORIZONTALLY. |
| | |
| | JAMES A. WITMER CBO |