2013-10-22 06:45:55BUILDING PLAN REVIEW
 PERMIT:13100263
 ADD: 1771 PALM BEACH LAKES # W309
 CONT: TO BE DETERMINED
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1STT REVIEW
 DATE: OCT. 22/2013
 ACTION:PB OUTLET MALLS:
 BUILDING PROVISO:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
  
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) SHEET A10.1:
 1A) 2010 FLORIDA ACCESSIBILITY CODE, 803.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE ROOM UNLESS A CLEAR
 FLOOR OR GROUND SPACE COMPLYING WITH 305.3 IS PROVIDED
 BEYOND THE ARC OF THE DOOR SWING.
  
 1B) 803.4 BENCHES.
 A BENCH COMPLYING WITH 903 SHALL BE PROVIDED WITHIN THE
 ROOM. 903.4 BACK SUPPORT. THE BENCH SHALL PROVIDE FOR
 BACK SUPPORT OR SHALL BE AFFIXED TO A WALL. BACK
 SUPPORT SHALL BE 42 INCHES (1065 MM) LONG MINIMUM AND
 SHALL EXTEND FROM A POINT 2 INCHES (51 MM) MAXIMUM
 ABOVE THE SEAT SURFACE TO A POINT 18 INCHES (455 MM)
 MINIMUM ABOVE THE SEAT SURFACE. BACK SUPPORT SHALL BE
 21/2 INCHES (64 MM) MAXIMUM FROM THE REAR EDGE OF THE
 SEAT MEASURED HORIZONTALLY.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715