| 2013-10-16 07:06:01 | BUILDING PLAN REVIEW |
| | PERMIT: 13100150 |
| | ADD: 1865 PALM BEACH LAKES BLDG "B1-FOUNDATION" |
| | CONT: EMJ |
| | TEL: (423) 855-6857 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: WED. OCT 16/2013 |
| | ACTION: DENIED |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | |
| | 1) SHEET S001. MISSING THE SOILS REPORT WHICH WILL |
| | PROVIDE THE SAFE MINIMUM BEARING VALUE. 2010 FBC-B |
| | 1803.5.2 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, |
| | STRENGTH OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR |
| | WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED |
| | IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE |
| | PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION |
| | BE CONDUCTED. |
| | PLEASE PROVIDE THE SOILS REPORT FROM ESC DATE JUNE 16, |
| | 2012 PROJECT NUMBER: 25-1847-C. |
| | |
| | 2) SHEET S001. THIS SWHEET INDICATES THIS BUILDING TO |
| | BE TILT WALL CONCRETE WALL PANEL CONSTRUCTION, THIS |
| | TYPE OF CONSTRUCTION REQUIRES A RESIDENT INSPECTOR PER |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION SECTION |
| | 110.3.9. PLEASE CONTACT THE MANAGER OF THE RESIDENT |
| | INSPECTOR PROGRAM KEN CONRAD FOR FORMS AND OTHER |
| | IMPORTANT REQUIREMENTS THAT WILL NEED TO BE MET BEFORE |
| | PERMIT ISSUANCE. |
| | MANAGER OF RESIDENT INSPECTOR PROGRAM: KEN CONRAD |
| | TEL 561-805-6666 |
| | E-MAIL: [email protected] |
| | |
| | 3) FOUNDATIONDETAIL PLAN S501 FOUNDATION DETAIL # 4 |
| | INDICATES TILT WALL PANELS BUT THE PLANS DO NOT |
| | INDICATE EMBEDS FOR TILT WALL CONSTRUCTION NEITHER DOES |
| | S101 OR S102. |
| | |
| | 4) THERE IS NO SITE PLAN PROVIDING THE LOCATION OF THIS |
| | BUILDING, NO DIMENSION LINES TO PROPERTY LINES OR |
| | ASSUMED PROPERTY LINES BETWEEN BUILDINGS OR NO MINIMUM |
| | BUILDING TYPE PROVIDED, |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 107.3.5.1.1. COMMERCIAL BUILDINGS, MINIMUM PLAN REVIEW |
| | CRITERIA. |
| | |
| | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |