| 2013-10-19 10:49:41 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. SIGNAGE TO BE SUBMITTED SEPARATELY (ADVISORY ONLY). |
| | |
| | 2. NEW FIXTURES SHOWN. NO ELECTRICAL REVIEW HAS BEEN |
| | DONE AT THIS TIME BUT PLEASE BE ADVISED THAT A SEPARATE |
| | ELECTRICAL PERMIT (WITH PLANS) WILL BE REQUIRED |
| | (ADVISORY ONLY). |
| | |
| | 3. REVISE PLAN TO SHOW OCCUPANCY CLASSIFICATION AND |
| | OCCUPANT LOAD FOR THE EXISTING BUILDING AND EXTERIOR |
| | COURTYARD. IT APPEARS THAT THE COURTYARD AREA IS |
| | CURRENTLY USED AS STORAGE AND WILL NOW BE A2. 1300 |
| | SF/15 IS AN OCCUPANT LOAD OF 87 FOR THE COURTYARD. |
| | OCCUPANT LOAD OF EXISTING RESTAURANT NOT SHOWN AND |
| | CANNOT BE DETERMINED AS KITCHEN/BATHROOM/WAITING AREAS |
| | NOT SHOWN. |
| | |
| | PROVIDE A LIFE SAFETY PLAN, FBC CHAPTER 10. EXITING |
| | STRATEGY NOT CLEAR. A DOOR IS SHOWN AS "EMERGENCY |
| | EGRESS," EXIT SIGNS SHOWN, BUT EXITING PATH NOT SHOWN. |
| | SEE ALSO FBC 1008.1.2 AND 1008.1.10. INCLUDE ELEVATION |
| | CHANGES, IF ANY, WHICH EXIST THROUGHOUT THE PROPOSED |
| | MEANS OF EGRESS PATH. |
| | |
| | 4. PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD |
| | REQUIRED, FAC9N-3, FBC 107 (DOOR). INDICATE HARDWARE |
| | AND THRESHOLD OPTIONS, SEE FBC 1008.1.10 AND FBC 2010 |
| | ACCESSIBILITY 404. |
| | |
| | 5. PROVIDE A DETAIL FOR THE PROPOSED GATE. CODE |
| | REFERENCE AND REQUIREMENTS CANNOT BE PROVIDED AT THIS |
| | TIME, SEE ITEM 3. IF THERE ARE NO CODE REQUIREMENTS FOR |
| | THE GATE, THIS MAY NOT BE REQUIRED. |
| | |
| | 6. TWO COMPLETE SETS OF PERMIT DOCUMENTS REQUIRED, FBC |
| | 107. ONLY ONE SET OF PLANS PROVIDED. THE CRA |
| | INFORMATION IS NOT REQUIRED FOR PERMITTING. |
| | |
| | |
| | |
| | |
| | |