2013-10-18 10:06:27BUILDING PLAN REVIEW
 PERMIT: 13090692
 ADD: 1731 PALM BEACH LAKES # E307
 CONT: TO BE DETERMINED
 TEL: (561)373-3902
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRIDAY OCT. 18/ 2013
 ACTION: DENIED
  
 1) SHEET A-4.1 LIFE SAFETY SHEET & A-2.0 FLOOR PLAN
 INDICATE THE 2ND REQUIRED EXIT THROUGH THE STORAGE
 ROOM, THE EXCEPTION PROVIDED UNDER 2010 FBC-B 1014.2
 EXCEPTION # 2 HAS FOUR REQUIREMENTS, THIS DESIGN DOES
 NOT MEET THE PORTION ( 2.4.) THERE IS A DEMARCATED,
 MINIMUM 44-INCH-WIDE (1118 MM) AISLE DEFINED BY FULL-
 OR PARTIAL-HEIGHT FIXED WALLS OR SIMILAR CONSTRUCTION
 THAT WILL MAINTAIN THE REQUIRED WIDTH AND LEAD DIRECTLY
 FROM THE RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS.
  
 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES.
 EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH
 THIS SECTION.
  
 1. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH
 ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE
 SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE
 ACCESSORY TO ONE OR THE OTHER, ARE NOT A GROUP H
 OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS
 TRAVEL TO AN EXIT.
  
 EXCEPTION: MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 ADJOINING OR INTERVENING ROOMS OR SPACES IN A GROUP H,
 S OR F OCCUPANCY WHEN THE ADJOINING OR INTERVENING
 ROOMS OR SPACES ARE THE SAME OR A LESSER HAZARD
 OCCUPANCY GROUP.
  
 2. AN EXIT ACCESS SHALL NOT PASS THROUGH A ROOM THAT
 CAN BE LOCKED TO PREVENT EGRESS.
  
 3. MEANS OF EGRESS FROM DWELLING UNITS OR SLEEPING
 AREAS SHALL NOT LEAD THROUGH OTHER SLEEPING AREAS,
 TOILET ROOMS OR BATHROOMS.
  
 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE
 ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
  
 EXCEPTIONS:
  
 1. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH A KITCHEN
 AREA SERVING ADJOINING ROOMS CONSTITUTING PART OF THE
 SAME DWELLING UNIT OR SLEEPING UNIT.
  
 2. MEANS OF EGRESS ARE NOT PROHIBITED THROUGH
 STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE
 FOLLOWING ARE MET:
  
 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS
 THAT FOUND IN THE MAIN RETAIL AREA;
  
 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS
 THROUGH THE STOCKROOM;
  
 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE
 EGRESS SIDE; AND
  
 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118
 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT FIXED
 WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE
 REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA
 TO THE EXIT WITHOUT OBSTRUCTIONS.
  
  
 PROVISO
 :PB OUTLET MALLS:
 BUILDING PROVISO:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  