| Date |
Text |
| 2013-09-18 15:21:22 | BUILDING PLAN REVIEW |
| | PERMIT: 13090397 |
| | ADD: 1771 PALM BEACH LAKES SUITE # W-317 |
| | CONT: TBD |
| | TEL: (561)373-3902 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: SEPT 18/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A3.0 THE BACK EXIT WILL NEED TO COMPLY WITH: |
| | 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES. |
| | EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH |
| | THIS SECTION. |
| | 4) EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| | ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES |
| | EXCEPTION # 2 |
| | COMPLIED 2 MEANS OF EGRESS ARE NOT PROHIBITED THROUGH |
| | STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE |
| | FOLLOWING ARE MET: |
| | COMPLIED 2.1. THE STOCK IS OF THE SAME HAZARD |
| | CLASSIFICATION AS THAT FOUND IN THE MAIN RETAIL AREA; |
| | COMPLIED 2.2. .NOT MORE THAN 50 PERCENT OF THE EXIT |
| | ACCESS IS THROUGH THE STOCKROOM; |
| | COMPLIED 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING |
| | FROM THE EGRESS SIDE; AND |
| | DENIED 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE |
| | (1118 MM) AISLE DEFINED BY FULL- OR PARTIAL-HEIGHT |
| | FIXED WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN |
| | THE REQUIRED WIDTH AND LEAD |
| | DIRECTLY FROM THE RETAIL AREA TO THE EXIT WITHOUT |
| | OBSTRUCTIONS. |
| | |
| | 2) SHEET A6.2 DETAIL "D" ACCESSIBLE DRESSING ROOM" TO |
| | COMPLY WITH 2010 FL ACCESSIBLITY CODE 903.4 BACK |
| | SUPPORT. |
| | THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE |
| | AFFIXED TO A WALL. BACK SUPPORT SHALL BE 42 INCHES |
| | (1065 MM) LONG MINIMUM AND SHALL EXTEND FROM A POINT 2 |
| | INCHES (51 MM) MAXIMUM ABOVE THE SEAT SURFACE TO A |
| | POINT 18 INCHES (455 MM) MINIMUM ABOVE THE SEAT |
| | SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES (64 MM) |
| | MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED |
| | HORIZONTALLY. |
| | ADVISORY 903.4 BACK SUPPORT. TO ASSIST IN TRANSFERRING |
| | TO THE BENCH, CONSIDER PROVIDING GRAB BARS ON A WALL |
| | ADJACENT TO THE BENCH, BUT NOT ON THE SEAT BACK. IF |
| | PROVIDED, GRAB BARS CANNOT OBSTRUCT TRANSFER TO THE |
| | BENCH. |
| | |
| | 3) SHEET A7.0 CASH WRAP DETAILS PROVIDE COMPLIANCE WITH |
| | 2010 FL ACCESSIBILITY CODE : |
| | 904.3.2 COUNTER. |
| | THE COUNTER SURFACE HEIGHT SHALL BE 38 INCHES (965 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE TOP OF |
| | THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES (51 MM) |
| | MAXIMUM ABOVE THE TOP OF THE COUNTER SURFACE ON THE |
| | AISLE SIDE OF THE CHECK-OUT COUNTER. |
| | 904.3.3 CHECK WRITING SURFACES. |
| | WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY |
| | WITH 902.3. |
| | |
| | 4) PB OUTLET MALLS: BUILDING PROVISO: |
| | A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| | CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| | CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| | PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| | CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| | HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| | WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| | DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| | NOTARIZED. |
| | |
| | 5) ARCHITECTS SIGNATURE IS A COPY. PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY |
| | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN |
| | PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | FL ADMIN CODE 61G16.003 ARCHITECTS |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |
| | . |
| | |