| Plan Review Notes For Permit 13081099 |
| Permit Number |
13081099 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2013-10-25 09:13:56 | 10-25/13 TALKED TO ANTHONY SABA. HE SAID OK TO DO | | | PROVISO. JG. | | 2013-10-23 18:02:16 | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | * 1- SURVEY SUBMITTED: NEED SURVEYOR'S ORIGINAL | | | SIGNATURE, NOT COPY. CHAPTER 472 FL. ST. | | | ** 2- REVISE ENERGY CALCULATIONS SUBMITTED AND | | | COORDINATE WITH FLOOR PLANS: *A)PROVIDE LEGIBLE FRONT | | | PAGE. **B)THERE IS NOT CRAWL SPACE. ***C)ROOF DECK IS | | | NOT INSULATED. ****D)THERE IS AN ATTIC (SEE DEFINITION | | | OF ATTIC). *****E) WHY GABLE AREA ON PAGE 2 OF 5 IS | | | 24FT IF THIS IS A FLAT ROOF?. ******F)REVISE THE | | | WINDOWS OVERHANG SEPARATION ON PAGE 3 OF 5 TO MATCH | | | PLANS. | | | ***3- REVISE TYPICAL WALL SECTION TO SHOW WALL | | | INSULATION VALUE AS SPECIFIED ON THE ENERGY | | | CALCULATIONS(R-5). | | | ****4- SUBMIT ENGINEER RAS 117 CALCULATIONS WITH | | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE. CHAPTER 471 FL. | | | ST. | | | *****5- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLION FOR | | | DOUBLE SLIDING WINDOWS ON SOUTH ELEVATION. | | | |
|