| Plan Review Notes For Permit 13080924 |
| Permit Number |
13080924 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-09-12 09:51:02 | BUILDING PROVISO: | | | 1) SHEET A1 EGRESS THROUGH STOCK ROOM TO COMPLY WITH: | | | 2010 FBC-B 1014.2 EXCEPTION # 2 | | | MEANS OF EGRESS ARE NOT PROHIBITED THROUGH STOCKROOMS | | | IN GROUP M OCCUPANCIES | | | WHEN ALL OF THE FOLLOWING ARE MET: | | | | | | 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS | | | THAT FOUND IN THE MAIN RETAIL AREA; | | | | | | 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS | | | THROUGH THE STOCKROOM; | | | | | | 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE | | | EGRESS SIDE; AND | | | PLEASE SHOW COMPLIANCE WITH: | | | 2.4 THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118 | | | MM) AISLE DEFINED BY FULL- OR | | | PARTIAL-HEIGHT FIXED WALLS OR SIMILAR CONSTRUCTION THAT | | | WILL MAINTAIN THE REQUIRED WIDTH | | | AND LEAD DIRECTLY FROM THE RETAIL AREA TO THE EXIT | | | WITHOUT OBSTRUCTIONS. | | | | | | 2) PROVISO: BREAK ROOM SINK HEIGHT TO COMPLY WITH: 2010 | | | FBC-ACCESSIBILITY CODE 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE | | | 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|