| Plan Review Notes For Permit 13080586 |
| Permit Number |
13080586 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2013-09-23 18:00:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] | | | | | | 1. FBC 2010 RESIDENTIAL: | | | | | | SPANS NOT CORRECT, AND THEREFORE CANNOT DETERMINE | | | WHETHER OR NOT ANCHOR SPACING OF 10" COMPLIES. | | | | | | FOR INSTANCE - OPENING 1, 47 X 86, SPAN IS SHOWN AS 4', | | | VERTICAL INSTALLATION. 86" PLUS EDGE DISTANCE (1 1/2" | | | TOP AND BOTTOM) SHOULD BE 89" SPAN. 8' SPAN, PANELMATE, | | | 60PSF (SEE PRODUCT APPROVAL) APPEARS TO REQUIRE 5" | | | SPACING (PRODUCT APPROVAL SUBMITTED IS DIFFICULT TO | | | READ). | | | | | | SPAN SHOULD BE THE DIMENSION OF ANCHOR TO ANCHOR. | | | |
|