Notes
Date Text
2013-09-27 10:05:25BUILDING PLAN REVIEW
 PERMIT: 13080547
 ADD: 509 S OLIVE AVE SUITE # ????
 CONT: MVP
 TEL: (561)214-0226
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE:SEPT 27/ 2013
 ACTION: PROVISO
 1) SHEET # 1, PLEASE SEE RESTROOM REVIEW DOORS IN
 SERIES 2010 FL ACCESS CODE 404.2.6. THE DISTANCE
 BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES
 IN SERIES SHALL BE 48 INCHES (1220 MM) MINIMUM PLUS THE
 WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE.
  
 2010 FL ACCESSIBILITY CODE 603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE
 PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE.
 EXCEPTIONS:
 2. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR
 INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH
 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE
 DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE
 CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY
 FIXTURE.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
2013-08-29 10:56:54BUILDING PLAN REVIEW
 PERMIT: 13080547
 ADD: 509 S OLIVE AVE SUITE # ????
 CONT: MVP
 TEL: (561)214-0226
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: AUGUST 29/ 2013
 ACTION: DENIED
  
 1) THIS PLANS CANNOT BE ISSUED UNTIL PERMIT # 13070893
 IS ISSUED.
  
 2) THE PLANS ARE NOT CLEAR AS IF THE RESTROOM/ BATHROOM
 IS TO BE USED AS A SINGLE USER SINCE THE SHOWER DOES
 NOT HAVE ITS OWN PRIVACY IF THE HALLWAY DOOR IS NOT
 LOCKED.
  
 3) THE SHOWER IS NOT SHOWN AS A ACCESSIBLE SHOWER 2010
 FL ACCESS CODE 2010 FBC-B 213.2.1./ 608.2.1 OR 608.2.3.
 PROVIDE DETAIL WITH SEAT, GRAB BARS & CONTROLS.
  
 4) PLEASE REVIEW DOORS IN SERIES 2010 FL ACCESS CODE
 404.2.6.
  
  
  
  