2013-09-24 17:47:46BUILDING PROVISO:
 SHEET A2.01 & A3.01
 DOOR # 4
 EXIT PASSAGEWAY
 2010 FBC-B 402.4.5.1.
 1 HOUR FIRE RATED DOOR ASSEMBLY
 402.4.5.1 EXIT PASSAGEWAYS.
 WHERE EXIT PASSAGEWAYS PROVIDE A SECONDARY MEANS OF
 EGRESS FROM A TENANT SPACE,
 DOORWAYS TO THE EXIT PASSAGEWAY SHALL BE PROTECTED BY
 1-HOUR FIRE DOOR ASSEMBLIES THAT
 ARE SELF- OR AUTOMATIC-CLOSING BY SMOKE DETECTION IN
 ACCORDANCE WITH SECTION 715.4.8.3
  