| 2013-08-21 12:57:15 | BUILDING PLAN REVIEW |
| | PERMIT: 13080440 |
| | ADD: 301 53RD ST UNIT A |
| | CONT: BESA CONSTRUCTION |
| | TEL: (561)605-3399 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: AUGUST 21/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE |
| | FLORIDA BUILDING CODE 2010 CHAPTER 1 ADMINISTRATION |
| | 107.1 WHO EVER THE DESIGNER IS FOR THE BUILDING SET OF |
| | PLANS WILL NEED TO PRINT, SIGN THEIR NAME AND LICENSE |
| | NUMBER ON THE PLANS, FOR EACH OF THE TRADES. THE CGC |
| | CAN ONLY DESIGN THE BUILDING PORTTION OF PLANS, AND |
| | THEY HAVE TO ALSO BE THE ONES TO COMPLETE THE WORK |
| | UNDER THE PERMIT, THIS GOES FOR EACH OF THE TRADES |
| | INVOLED. |
| | |
| | 2) THE PLANS DO NOT PROVIDE WHAT THE UNIT LOOKED LIKE |
| | BEFORE THE REMODEL, WE ARE UNABLE TO KNOW WHAT IS |
| | EXISTING AND WHAT IS NEW. PLEASE PROVIDE EXISTING AND |
| | PROPOSED FLOOR PLANS. CITY OF WEST PALM BEACH LOCAL |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE 2010 CHAPTER 1 |
| | ADMINISTRATION 107.2.1 CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. |
| | |
| | 3) PLEASE IDENTIFY IF THIS UNIT IS A TOWNHOUSE UNIT OR |
| | IS THIS A TOWNHOUSE UNIT, IT WILL DETERMINE TO WHICH |
| | CODE BOOK WE CONDUCT OUR REVIEW. |
| | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE 2010 CHAPTER 1 ADMINISTRATION 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIED. |
| | |
| | 4) THE PLANS INDICATE WHAT APPEARS TO BE A DOOR OPENING |
| | TO THE EXTERIOR FROM THE RENOVATED BATHROOM, IS THIS A |
| | NEW OPENING, IF SO PLEASE PROVIDE THE TYPE OF EXTERIOR |
| | WALLS ARE BEING CONSTRUCTEDPROVIDE FINSHES AND PRODUCT |
| | APPROVALS FOR THE NEW DOOR OPENING. 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 5) PLANS APPEAR THAT PARTS OF THE BATHROOM FLOOR WILL |
| | BE REMOVED FOR THE NEW PLUMBING WASTE PIPING. PLEASE |
| | PROVIDE HOW THE FLOOR SLAB IS GOING TO BE REPAIRED IF |
| | IT IS A CONCRETE SLAB. 107.2.1.3 ADDITIONAL INFORMATION |
| | IS REQUIRED. PLEASE PROVIDE DETAILS FOR COMPLIANCE |
| | WITH: |
| | 5A) 2010 FBC 1816.1.4 |
| | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE |
| | PREVENTION, CHEMICALLY TREATED SOIL SHALL BE PROTECTED |
| | WITH A MINIMUM 6 MILLIMETER VAPOR RETARDER TO PROTECT |
| | AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE |
| | VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. ANY |
| | WORK, INCLUDING PLACEMENT OF REINFORCING STEEL, DONE |
| | AFTER CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS |
| | POURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID |
| | PENETRATING OR DISTURBING TREATED SOIL. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |