| Date |
Text |
| 2013-08-17 11:57:20 | BUILDING PLAN REVIEW |
| | PERMIT: 13080387 |
| | ADD: 2414 FORIDA AVE |
| | CONT: TBD |
| | TEL: (561)318-5243 MICHAEL NELSON |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: AUGUST 17/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) THIS IS THE SECOND PHASE OF PERMITING, PLEASE SHOW |
| | COMPLIANCE WITH THE PROVISO FROM PERMIT 12120673 AND |
| | THE CURENT PERMIT APPLICATION 13080387 THE COMBINED |
| | DOLLAR VALUE OF $15,000.00 . |
| | PROVISO FROM 12120673, BUILDING PROVISO: |
| | 2010 FL ACCESSIBILITY CODE 202.4 & ADVISORY. PROVIDE |
| | INFORMATION REGARDING THE OTHER ACCESSBILE FEATURES & |
| | PROPOSED . |
| | |
| | PLEASE NOTE THE COMBINED VALUE OF THE 2 PERMITS IS |
| | $15,000.00 PLEASE PROVIDE COMPLIANCE WITH SHOWING |
| | $3,000 DOLLARE IN ACCESSIBLE UPGRADES. |
| | 2010 FLORIDA ACCESSIBLITY CODE. |
| | 202.4.1 DISPROPORTIONATE COST. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| | AN INACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| | DISPROPORTIONALITY. |
| | WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| | OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| | DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| | ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| | ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| | FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| | ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| | ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| | RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| | DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| | ALARMS. |
| | |
| | 202.4.3 SERIES OF SMALLER ALTERATIONS. |
| | THE OBLIGATION TO PROVIDE AN ACCESSIBLE PATH OF TRAVEL |
| | MAY NOT BE EVADED BY PERFORMING A SERIES OF SMALL |
| | ALTERATIONS TO THE AREA SERVED BY A SINGLE PATH OF |
| | TRAVEL IF THOSE ALTERATIONS COULD HAVE BEEN PERFORMED |
| | AS A SINGLE UNDERTAKING. |
| | |
| | 202.4.3.1 |
| | IF AN AREA CONTAINING A PRIMARY FUNCTION HAS BEEN |
| | ALTERED WITHOUT PROVIDING AN ACCESSIBLE PATH OF TRAVEL |
| | TO THAT AREA, AND SUBSEQUENT ALTERATIONS OF THAT AREA, |
| | OR A DIFFERENT AREA ON THE SAME PATH OF TRAVEL, ARE |
| | UNDERTAKEN WITHIN THREE YEARS OF THE ORIGINAL |
| | ALTERATION, THE TOTAL COST OF ALTERATIONS TO THE |
| | PRIMARY FUNCTION AREAS ON THAT PATH OF TRAVEL DURING |
| | THE PRECEDING THREE YEAR PERIOD SHALL BE CONSIDERED IN |
| | DETERMINING WHETHER THE COST OF MAKING THAT PATH OF |
| | TRAVEL ACCESSIBLE IS DISPROPORTIONATE. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |