2013-09-03 16:48:18****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. SEE FBC 1603.1.4, WIND DESIGN CRITERIA, WIND SPEED
 IN BOTH VULT AND VASD TO BE PROVIDED. 150MPH WAS NOT
 CLEAR; VULT OR VASD? MINIMUM FOR THIS LOCATION IS
 170MPH VULT / 132 VASD. PLEASE CLARIFY.
  
 ENGINEER MAY SEND A LETTER OF CLARIFICATION VIA EMAIL.
  
 3RD REVIEW, WIND SPEEDCHANGED BUT EXPOSURE WAS CHANGED
 FROM D TO B. PLEASE SEE THIS STRUCTURE ON AN AERIAL. IF
 YOU BELIEVE THIS IS EXPOSURE B RATHER THAN D, PLEASE
 CALL ME TO DISCUSS PRIOR TO RESUBMITTAL. OTHERWISE,
 REVISE BACK TO EXPOSURE B. THIS STRUCTURE IS LOCATED ON
 THE INTRACOASTAL.
  
  
2013-08-22 21:36:16****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. SEE FBC 1603.1.4, WIND DESIGN CRITERIA, WIND SPEED
 IN BOTH VULT AND VASD TO BE PROVIDED. 150MPH WAS NOT
 CLEAR; VULT OR VASD? MINIMUM FOR THIS LOCATION IS
 170MPH VULT / 132 VASD. PLEASE CLARIFY.
  
 ENGINEER MAY SEND A LETTER OF CLARIFICATION VIA EMAIL.
  