Plan Review Notes For Permit 13080121
Permit Number 13080121
Review Stop B
Sequence Number 1
Notes
Date Text
2013-09-12 11:50:23BUILDING PROVISO:
 1) SHEET A3.1 2010 FL ACCESSIBILITY CODE GRAB BARS,
 POSITION OF;
 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE
 INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH
 FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE.
  
 2) SHEET A1.2 DETAIL #9 CASH WRAP, PLEASE PROVIDE
 COMPLIANCE WITH:
 2010 FL ACCESSIBILITY CODE 904.3.3 CHECK WRITING
 SURFACES.
 WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY
 WITH 902.3.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]