| Plan Review Notes For Permit 13071103 |
| Permit Number |
13071103 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-08-08 10:51:13 | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | | | | 1. THE COMMON AREA TOILET FACILITIES APPEAR TO BE OVER | | | 500' FROM THE STORE ENTRANCE. PLEASE VERIFY THE PUBLIC | | | ACCESS DISTANCE WITH THE PALM BEACH OUTLET MALL. THE | | | ROUTE TO THE STORE FACILITIES IS THROUGH A STORAGE | | | (STOCK) AREA. | | | | | | 403.3.2 LOCATION OF TOILET FACILITIES IN OCCUPANCIES | | | OTHER THAN COVERED MALLS. | | | IN OCCUPANCIES OTHER THAN COVERED MALL BUILDINGS, THE | | | REQUIRED PUBLIC AND EMPLOYEE TOILET FACILITIES SHALL BE | | | LOCATED NOT MORE THAN ONE STORY ABOVE OR BELOW THE | | | SPACE REQUIRED TO BE PROVIDED WITH TOILET FACILITIES, | | | AND THE PATH OF TRAVEL TO SUCH FACILITIES SHALL NOT | | | EXCEED A DISTANCE OF 500 FEET (152 M). | | | | | | 403.3.1 ACCESS. | | | THE ROUTE TO THE PUBLIC TOILET FACILITIES REQUIRED BY | | | SECTION 403.3 SHALL NOT PASS THROUGH KITCHENS, STORAGE | | | ROOMS OR CLOSETS. ACCESS TO THE REQUIRED FACILITIES | | | SHALL BE FROM WITHIN THE BUILDING OR FROM THE EXTERIOR | | | OF THE BUILDING. ALL ROUTES SHALL COMPLY WITH THE | | | ACCESSIBILITY REQUIREMENTS OF THE FLORIDA BUILDING | | | CODE, ACCESSIBILITY. THE PUBLIC SHALL HAVE ACCESS TO | | | THE REQUIRED TOILET FACILITIES AT ALL TIMES THAT THE | | | BUILDING IS OCCUPIED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | |
|