Text |
| 2013-08-09 08:37:49 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #1 | | | DENIED: | | | | | | 1. SHEET A1.01 SHOWS WHAT APPEARS TO BE AN OFFICE AREA | | | WITH 2 ACCESSABLE RESTROOMS. THE RESTROOMS WOULD NOT | | | MEET THE REQUIREMENTS OF THE FBC ACCESSIBILITY CODE | | | 604.3.1 SIZE. | | | CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES | | | (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | | WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED | | | PERPENDICULAR FROM THE REAR WALL. | | | 604.8.1.6 LAVATORY. | | | IN NEW CONSTRUCTION, THE WHEELCHAIR ACCESSIBLE TOILET | | | COMPARTMENT SHALL CONTAIN AN ACCESSIBLE LAVATORY WITHIN | | | IT, WHICH MUST BE AT LEAST 19 INCHES WIDE BY 17 INCHES | | | DEEP, NOMINAL SIZE, AND WALL-MOUNTED. THE LAVATORY | | | SHALL BE MOUNTED SO AS NOT TO OVERLAP THE CLEAR FLOOR | | | SPACE AREAS REQUIRED BY SECTION 604 FOR THE WHEELCHAIR | | | ACCESSIBLE TOILET COMPARTMENT AND SHALL COMPLY WITH | | | SECTION 606. SUCH LAVATORIES SHALL BE COUNTED AS PART | | | OF THE REQUIRED FIXTURE COUNT FOR THE BUILDING. SEE | | | ALSO SECTION 213.3.4. | | | | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 | | | | | | |
|