| 2013-10-17 09:54:52 | BUILDING PLAN REVIEW |
| | PERMIT: 13070610 |
| | ADD: 720 S SAPODILLA AV- ROOFTOP |
| | CONT: HAYDEN PROFESSIONAL SERVICES |
| | TEL: (772)781-1512 |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 4TH REVIEW |
| | DATE: 10/17/2013 |
| | ACTION: PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | |
| | 1) SHEET C4 THE ELEVATIONS INDICATE WHAT APPEARS TO BE |
| | TRIM ON THE CONCEALMENT SCREENS (CONCEALMENT SCREENS- |
| | CODE COMPLIANT/ MEETS NON-COMBUSTIBILITY REQUIREMENT) |
| | AND ARCHITECTURAL DECOR (ARCHITECTURAL DECOR/ 3" |
| | HARDCOATED FOAM MOLDINGS/ COMBUSTIBLE, NOT COMPLIANT |
| | FLAME SPREAD GREATER THAN 50 DOES NOT MEET ASTM E84 OR |
| | UL723) TO MATCH THE BUILDING ON THE MODULAR BUILDING, |
| | PLEASE PROVIDE COMPLIANCE WITH: |
| | |
| | 2010 FBC-B 1406.2.2 TYPE I, II, III AND IV |
| | CONSTRUCTION. |
| | ON BUILDINGS OF TYPE I, II, III AND IV CONSTRUCTION, |
| | EXTERIOR WALL COVERINGS SHALL BE PERMITTED TO BE |
| | CONSTRUCTED OF WOOD IN ACCORDANCE WITH SECTION 1405.5, |
| | OR OTHER EQUIVALENT COMBUSTIBLE MATERIAL, COMPLYING |
| | WITH THE FOLLOWING LIMITATIONS: |
| | (2.) COMBUSTIBLE ARCHITECTURAL TRIM SHALL BE LIMITED TO |
| | 40 FEET (12 192 MM) IN HEIGHT ABOVE GRADE. |
| | |
| | |