| Plan Review Notes For Permit 13070553 |
| Permit Number |
13070553 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2013-08-05 18:25:41 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. REVISE FLOOR PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION FOR BEDROOMS; FBC R310, FBC EB 604.1. THE | | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | IF NON COMPLIANT EMERGENCY ESCAPE AND RESCUE OPENINGS | | | ARE PROPOSED, PROVIDE THE FOLLOWING INFORMATION : | | | **INFORMATION REQUIRED FOR BEDROOM 3 WINDOWS ONLY AS | | | BEDROOM 1 AND 2 HAVE COMPLIANT WINDOWS | | | | | | | | | REVISE PLAN TO STATE WHAT TYPE OF WINDOW IS THERE NOW | | | IN THE BEDROOMS - AWNING, CASEMENT, SINGLE HUNG? | | | **COMMENT NOT ADDRESED** | | | | | | REVISE PLAN TO STATE WHAT THE EXISTING CLEAR OPENING | | | DIMENSIONS ARE. CLEAR OPENING IS THE OPENING WHICH | | | EXISTS WHEN THE WINDOW IS FULLY OPEN. | | | **A SF DIMENSION WAS PROVIDED BUT WIDTH X HEIGHT | | | REQUIRED, STATE THIS IS EXISTING** | | | | | | | | | REVISE PLAN TO STATE WHAT THE PROPOSED CLEAR OPENING | | | DIMENSIONS ARE. THIS CAN BE OBTAINED FROM THE | | | MANUFACTURER. | | | **A SF DIMENSION WAS PROVIDED BUT WIDTH X HEIGHT | | | REQUIRED, STATE THAT THIS IS PROPOSED** | | | | | | | | | 2. VALUE TO INCLUDE LABOR AND MATERIALS, FBC 109. | | | PROVIDE A COPY OF THE CONTRACT FOR THIS JOB AS WELL AS | | | A COST BREAKDOWN. | | | **NOT ADDRESSED, PROVIDE THE WINDOW PURCHASE ORDER** | | | | | | 3. OK |
|