Plan Review Notes
Plan Review Notes For Permit 13070390
Permit Number 13070390
Review Stop B
Sequence Number 1
Notes
Date Text
2013-07-23 15:48:53BUILDING PLAN REVIEW
 PERMIT: 13070390
 ADD: PALM BEACH LAKES BLVD # W-117
 CONT: TBD (TO BE DETERMINED)
 TEL: (###)###-####
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: JULY 23/ 2013
 ACTION: BUILDING PROVISOS
  
 1) PB OUTLET MALLS:
 BUILDING PROVISO:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
  
 2) PROVISO: SHEET A-03 GENERIC ACCESSABLE STALL PLEASE
 REVIEW 2010 FLORIDA ACCESSIBILITY CODE 604.8.1.6
 LAVATORY. FIGURE 604.8.1.6 (GRAY BOX, FLORIDA SPECIFIC
 REQUIREMENT). IN NEW CONSTRUCTION, THE WHEELCHAIR
 ACCESSIBLE TOILET COMPARTMENT SHALL CONTAIN AN
 ACCESSIBLE LAVATORY WITHIN IT, WHICH MUST BE AT LEAST
 19 INCHES WIDE BY 17 INCHES DEEP, NOMINAL SIZE, AND
 WALL-MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT
 TO OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY
 SECTION 604 FOR THE WHEELCHAIR ACCESSIBLE TOILET
 COMPARTMENT AND SHALL COMPLY WITH SECTION 606. SUCH
 LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED
 FIXTURE COUNT FOR THE BUILDING. SEE ALSO SECTION
 213.3.4.
  
 3A) PROVISO: SHEET A2-1B ACCESSIBLE DRESSING ROOM THERE
 IS NO CLEAR TURNING AREA FOR THE WHEEL CHAIR. 2010
 FLORIDA ACCESSIBILITY CODE 803.2 A TURNING SPACE
 COMPLYING WITH 304 SHALL BE PROVIDED WITHIN THE ROOM.
  
 B) PROVISO: SHEET A2-1B NOR A6-3 DETAIL # 4, PROVIDE
 COMPLIANCE WITH 2010 FLORIDA ACCESSIBILITY CODE
 DRESSING ROOMS 803.4 BENCHES. A BENCH COMPLYING WITH
 903 SHALL BE PROVIDED WITHIN THE ROOM. 903.4 BACK
 SUPPORT. THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR
 SHALL BE AFFIXED TO A WALL. BACK SUPPORT SHALL BE 42
 INCHES (1065 MM) LONG MINIMUM AND SHALL EXTEND FROM A
 POINT 2 INCHES (51 MM) MAXIMUM ABOVE THE SEAT SURFACE
 TO A POINT 18 INCHES (455 MM) MINIMUM ABOVE THE SEAT
 SURFACE. BACK SUPPORT SHALL BE 21/2 INCHES (64 MM)
 MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED
 HORIZONTALLY.
  
 NOTE: SPECIFICATION SHEETS SP01 - SP22 ARE NOT PART OF
 THE PLAN REVIEW.
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy