| Date |
Text |
| 2013-11-25 18:58:02 | RESIDENTIAL (R3) GARAGE CONVERSION, FOURTH MECHANICAL |
| | REVIEW CHECKLIST. |
| | CODE: 2010 FBC. |
| | |
| | 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS. |
| | COMPLETE CALCULATIONS NEED TO BE DONE BASED ON THE |
| | BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF THE |
| | BUILDING AS REQUIRED BY SEC. 403.6.1 OF 2010 FBC-ENERGY |
| | CONSERVATION. ALSO, NEED TO SHOW THE MANUFACTURER AND |
| | MODEL NUMBERS (INDOOR AND OUTDOOR). |
| | |
| | ***NOTE: EQUIPMENT TO MATCH EQUIPMENT LISTED ON |
| | DRAWINGS SUBMITTED. |
| | |
| | ***EQUIPMENT SHOWN ON THE CALCULATIONS DOESN'T MATCH |
| | PLANS SUBMITTED AND CALCULATIONS ARE NOT DONE BASED ON |
| | THE ORIENTATION OF THE BUILDING. |
| | |
| | B) CALCULATIONS FOR REPLACEMENT EQUIPMENT NEED TO BE |
| | DONE BY AN A/C CONTRACTOR OR LICENSED FLORIDA ENGINEER |
| | AS REQUIRED BY SEC. 101.4.7.1.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. (REPEAT COMMENT). |
| | |
| | ****NOTE: THIS TO BE DONE ON A SEPARATE PERMIT. THIS |
| | PERMIT APPLICATION IS FOR THE GARAGE CONVERSION ONLY. |
| | |
| | |
| | |
| | 2- BEDROOM TO SHOW COMPLIANCE WITH THE RETURN AIR AND |
| | BALANCED RETURN AIR REQUIREMENTS OF SEC. R1602 OF 2010 |
| | FBC-RESIDENTIAL. (REPEAT COMMENT). |
| | |
| | 3- EQUIPMENT LISTED ON THE A/C PLAN, EQUIPMENT LISTED |
| | ON THE EQUIPMENT SIZING CALCULATIONS AND INFORMATION ON |
| | THE ENERGY CALCULATIONS NEED TO MATCH. CHECK SIZE AND |
| | SEER, ETC. REVISE AS REQUIRED TO MATCH. SEC. 103.2.2 OF |
| | 2010 FBC-ENERGY CONSERVATION. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |