| 2013-09-26 11:12:30 | RESIDENTIAL (R3) GARAGE CONVERSION, SECOND BUILDING |
| | REVIEW CHECKLIST. |
| | CODE: 2010 FBC. |
| | |
| | 1- ENGINEER TO USE CURRENT SEAL AS REQUIRED BY CHAPTER |
| | 471 FLORIDA STATUTE. SEAL THAT SAYS "CERTIFICATE" |
| | INSTEAD OF "LICENSE" IS NOT ALLOWED SINCE 2006. AND, |
| | CLARIFY WHY THERE IS AN EXPIRATION DATE OF 2/28/13 |
| | BELOW THE ENGINEER'S LICENSE NUMBER?. (REPEAT COMMENT). |
| | |
| | 2- SPECIFY TYPE OF WINDOW ON BEDROOM TO VERIFY |
| | COMPLIANCE WITH EGRESS REQUIREMENTS. SEC. R310 OF 2010 |
| | FBC-RESIDENTIAL. |
| | ***COMMENTS TO RESPONSE: |
| | A)INFORMATION SUBMITTED DOESN'T SPECIFY TYPE OF WINDOW. |
| | |
| | B) PROVIDE MANUFACTURER SPECS SHOWING THAT THE 36" X |
| | 50" SPECIFIED WINDOW MEETS THE EGRESS REQUIREMENTS. |
| | NEED TO VERIFY MIN. CLEAR WIDTH, MIN. CLEAR HEIGHT AND |
| | MIN. TOTAL CLEAR OPENING. |
| | |
| | 3- PROVIDE DETAILS AND SPECIFICATIONS SHOWING HOW |
| | OBTAINING R-6 VALUE IN THE CONCRETE BLOCK WALLS. |
| | ***COMMENTS TO RESPONSE: |
| | TYPICAL WALL DETAIL SUBMITTED SHOWS "REFLECTIX FOIL |
| | INSUL. R-3.79". THIS DOESN'T MEET THE R-6 VALUE. NEED |
| | TO USE ONLY THE R-VALUE OF THE INSTALLED INSULATION. |
| | SEC. 304.1.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | 4- ENERGY CALCULATIONS SUBMITTED; |
| | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING THE BUILDER'S NAME AND OWNER'S NAME. (SEC. |
| | 103.2.1.1.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | B) REVISE ROOF TYPE ON PAGE 3 OF 6 TO ADD THE FLAT ROOF |
| | AREA OF THE ADDITION. SEC. 103.2.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) WINDOWS SHOWN ON PLANS. (REPEAT COMMENT. NO |
| | SUBMITTED). |
| | ***NOTE: PLEASE MAKE SURE PRODUCT APPROVAL MEETS THE |
| | CALCULATED DESIGN PRESSURES. |
| | |
| | B) HURRICANE SHUTTERS IF WINDOWS DON'T HAVE HURRICANE |
| | IMPACT GLAZING AND FOR FRENCH DOORS (FRENCH DOORS NOA |
| | 09-0608.16 SUBMITTED IS FOR NON-IMPACT DOOR). |
| | ***COMMENTS TO RESPONSE: NOA 09-0114.02 SUBMITTED WAS |
| | CLOSED BY MIAMI-DADE. NEED CURRENT NOA. |
| | |
| | C) FRENCH DOORS THAT MEET THE DESIGN PRESSURES |
| | CALCULATED BY THE ENGINEER OF RECORD. NOA 09-0415.08 |
| | SUBMITTED DOESN'T MEET THOSE DESIGN PRESSURES. |
| | |
| | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL OF THE ABOVE PRODUCT |
| | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | 7- REVISE THE HURRICANE SHUTTERS INSTALLATION SCHEDULE. |
| | COORDINATE WITH NEW PRODUCT APPROVAL SUBMITTED. SEE |
| | ITEM #5(B) ABOVE. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 8- PROVIDE MANUFACTURER'S INFORMATION FOR DOORS AND |
| | WINDOWS U-FACTOR AND SHGC FACTOR AS SPECIFIED ON ITEM |
| | #7 OF THE ENERGY CALCULATIONS SUBMITTED. SEC. 103.2.2 |
| | OF 2010 FBC-ENERGY CONSERVATION. (REPEAT COMMENT. NOT |
| | ADDRESSED). |
| | |
| | |
| | *** PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS... |
| | |
| | |