| Plan Review Notes For Permit 13060048 |
| Permit Number |
13060048 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-06-05 16:13:05 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. REVISE THE FLOOR PLAN TO SHOW EXISTING CONDITIONS | | | FOR BEDROOMS (TYPE OF WINDOW) AND EXISTING CLEAR | | | OPENING SIZE AND PROPOSED CLEAR OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | THE CLEAR OPENING IS THE OPEN AREA CREATED WHEN THE | | | WINDOW IS IN THE OPEN POSITION, NOT THE MASONRY/FRAME | | | OPENING/WINDOW OVERALL SIZE. |
|