| Date |
Text |
| 2013-06-18 10:10:42 | BUILDING PLAN REVIEW |
| | PERMIT: 13051091 |
| | ADD: 1400 VILLAGE BLVD |
| | CONT: TBD |
| | TEL: (561)###-#### |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: JUNE 18/2013 |
| | ACTION: DENIED |
| | |
| | 1) THE SUBMITTED MODULAR PLAN IS A STATE APPROVED PLAN. |
| | SHEET C1LIST THE STATE APPROVED PLAN # DBI 12605 AS A |
| | APPROVED PLAN WITH THE APPROVAL NUMBER ON EVERY SHEET |
| | ON THE MODULAR BUILDING PORTION OF THE STATE WEBSITE. |
| | THE COVER LETTER THAT TIES TO THE MODULAR BUILDING |
| | REVIEW IS ALSO DIFFERENT FROM THE LETTER SUBMITTED. |
| | PLEASE INDICATE WHAT THE PURPOSE OF SIGNED AND SEALED |
| | PLANS ARE AND WHY ALL OF THE PLANS DO NOT HAVE THE |
| | STATE APPROVAL? IF THE APPROVAL IS GOING TO BE REMOVED |
| | FROM THIS UNIT AND A TOTAL REVIEW OF ALL TRADES TO |
| | OCCUR? |
| | |
| | 2) SHEET C1 UNDER THE HEADING OF AS BUILT LIST THIS |
| | MODULAR BUILDING WAS BUILT UNDER THE 2004 FBC-B BUT |
| | REFERENCES THE CURRENT CODE BASICALLY AS EQUAL. THE 170 |
| | MPH VULT = TO 132 VASD NOT THE 130 NOTED ON THE PLAN. |
| | FIGURE 1609A NOTE # 2 DOES ALLOW FOR LINEAR |
| | INTERPOLATION, PLEASE PROVIDE MORE INFORMATION? |
| | |
| | 3) PLEASE PROVIDE THE LENGTH OF TIME THE MANUFACTURED |
| | BUILDING IS TO BE ON SITE, NOTE THE TERM TEMORARY IN |
| | THE BUILDING CODE IS FOR NOT MORE THAN 6 MONTHS. 108.1. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |