| 2013-07-20 10:24:59 | BUILDING PLAN REVIEW |
| | PERMIT: 13051012 |
| | ADD: LAMBERTON |
| | CONT:TO BE DETERMINED |
| | TEL: (561)###-#### CONTACT? |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: JULY 20/2013 |
| | ACTION: DENIED |
| | |
| | 1) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | 2) FBC* 110.3.9 RESIDENT INSPECTOR (ON SITE INSPECTOR |
| | REQUIRED). SUBMIT INSPECTOR RESUME' AND LICENSE |
| | DOCUMENTS TO KEN CONRAD, MANAGER OF THE RESIDENT |
| | INSPECTOR PROGRAM. A RESIDENT INSPECTOR PROGRAM IS |
| | REQUIRED, ON THIS PROJECT, DUE TO BUILDINGS OVER 2 |
| | STORIES IN HEIGHT. |
| | KEN CONRAD |
| | TEL: 561-805-6666 |
| | E:MAIL: KCONRAD @WPB.ORG |
| | |
| | 3) PROJECT DOCS HEADING VIEW FOLDERS INDICATES THAT |
| | SPEC BOOKS WERE LOADED FOR REVIEW, PLEASE DELETE THESE |
| | FROM THE NEXT SUBMITTAL, THEY WILL NOT BE REVIEWED NOR |
| | WILL THEY RECEIVE A BATCH STAMP. |
| | |
| | 4) SHEET A0.02 INDEX OF DRAWINGS INDICATES A1.10, |
| | A1.20, A1.30, A1.40 & A1.50 SHOLD BE IN THIS SET OF |
| | PLANS, THEY ARE MISSING? 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 5) SHEET A0.10 SITE PLAN; |
| | |
| | 5A) PLEASE PROVIDE THE PARKING COUNT, PLEASE BREAK OUT |
| | BY SECTION PLEASE PROVIDE COUNT FOR FAIR HOUSING AND |
| | FOR FL ACCESSIBILITY FOR COMMON AREAS, RENTAL OR SALES |
| | OFFICE. |
| | FAIR HOUSING ANSI A117.1 4.3 |
| | 2010 FL ACCESS TABLE 208.2 |
| | |
| | 5B) PLEASE PROVIDE THE DISTANCE BETWEEN BUILDINGS, AND |
| | TTHE DISTANCE BETWEEN BUILDINGS FOR ASSUMED PROPERTY |
| | LINES TO COMPLY WITH 20 10 FBC-B TABLE 602 & T 705.8. |
| | |
| | 5C) BUILDING TYPE 8 DOES NOT HAVE ACCESSIBLE PARKING, |
| | FAIR HOUSING ANSI A117.1 1986 4.6 PARKING SPACES. |
| | |
| | 5D) THE SITE PLANS DO NOT PROVIDE CLARITY OR DETAILS IF |
| | THERE IS DROPPED CURBS OR CURB CUTS, CURB RAMPS FOR |
| | ACCESS AISLES OR CROSS WALKS, ANSI A 117.1 1986 |
| | 4.7 CURB RAMPS. |
| | |
| | 6) SHEET A4.00 SERIES WOOD VINYL PLANK, TILE FLOORING |
| | PLEASE PROVIDE TTHE REQUIRED STC RATING SHOWING |
| | COMPLIANCE WITH 2010 FBC-B 1207.3 STRUCTURE BORNE |
| | SOUND. |
| | |
| | 7) SHEET A5.00 UNIT TO UNIT AND UNIT TO CORRIDOR |
| | DETAILS DO NOT LIST THERE STC RATING, PLEASE SHOW |
| | COMPLIANCE WITH 2010 FBC-B 1207.2 AIR BORNE SOUND. |
| | |
| | 8) SHEET A7.01 DOOR SCHEDULE FOR UNIT EXTERIOR DOOR |
| | SCHEDULE DOOR MARK U-003 A PAIR OF FRENCH DOORS, WHERE |
| | WILL THIS BE USED ON THE EXTERIOR OF A UNIT, IT DOES |
| | NOT SHOW UP ON ANY OF THE FOUR HUNDRED SERIES OF |
| | DRAWINGS FOR UNITS. THE CONCERN IS THE PRODUCT APPROVAL |
| | SUBMITTED INDICATES PRESSURES OF +/- 90 WHICH INDICATES |
| | A 2 INCH HIGH THRESHOLD WILL BE INSTALLED, WILL FAIR |
| | HOUSING BE A CONCERN FOR THE LOCATION IT WIL BE |
| | INSTALLED? ANS A117.1 1986 4.13 DOORS. |
| | |
| | 9) SHEET A7.01 UNIT EXTERIOR DOOR SCHEDULE IS MISSING |
| | THE NOMINAL DESIGN WIND PRESSURES. |
| | |
| | 10) SHEET SG-N1 ROOF PRESSURE ZONES (1-3) AND OVER HANG |
| | ZONES (2 &5) ARE IN PSF, THE SUBMITTED NOA 12-0222.02 |
| | SHEET 5 OF 7 FOR ATTACHMENT IS EXPRESSED A MOMENT- MF |
| | (FT-LBS) PLEASE CONVERT TO PSF . THE NOA IS HIGHLIGHTED |
| | 2-10D RING SHANK NAILS 41.2 MF. |
| | |
| | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |